OSHA Inspection: STOLTZFUS R.V.'S, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STOLTZFUS R.V.'S, INC. in 3280 NORTH READING ROAD ROUTE 272, ADAMSTOWN, PA 19501 (NAICS 441210). OSHA activity number 340725191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stoltzfus R.V.'S, INC. — free Get an email when a new federal OSHA severe-injury report for Stoltzfus R.V.'S, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3280 NORTH READING ROAD ROUTE 272
City
ADAMSTOWN
State
PA
ZIP
19501
Mailing
ROUTE 272, P.O. BOX 564, ADAMSTOWN, PA 19501
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441210
Employees
15
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 17, 2015
Abate by
Jan 6, 2016
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides:   On or about June 23, 2015, at the site, technician(s) must perform repairs and inspections to the roofs of recreational vehicles (RV). Repairs include repairing and replacing a roof, repairing air condition units. Technician(s) exposed to a fall hazard of approximately ten feet to the lower level.    Or, In the alternative:    29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:   Abatement certification required within 10 days after the abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 17, 2015
Abate by
Jan 6, 2016
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.215(b)(9): 29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  On or about June 23, 2015, garage bay: The six inch Baldor electric bench grinder did not have an abrasive wheel tongue guard on either wheel exposing employees to struck by hazards from the high speed abrasive wheel.    Abatement certification is required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 17, 2015
Abate by
Jan 6, 2016
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  a) On or about June 23, 2015, garage bay: The middle 200 amp main electric service panel had an unused opening (position 26) covered by electric tape, exposing the energized bus bar.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.334 A02 I

Other-than-serious 1 instance 1 exposed
Issued
Dec 17, 2015
Abate by
Jan 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord- and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence for possible internal damage (such as pinched or  crushed outer jacket):  On or about June 23, 2015, rear of bay 2: An energized extension cord was not visually inspected prior to use and had damage to the outer sheath jacket exposing the internal insulated conductors.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Stoltzfus R.V.'S, INC.'s full OSHA safety record →