OSHA Inspection: Z ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of Z ENTERPRISES, INC. in RETAIL SPACE ALTERATION INTO RENTAL CAR OFFICE AND TUDOR SERVICE ACANTA MALL, TUN JOAQUIN SANTOS LANE AND PALE SAN VITORES ROAD, TAMUNING, GU 96913 (NAICS 236220). OSHA activity number 340725969.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Z Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Z Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
Z ENTERPRISES, INC.
Site address
RETAIL SPACE ALTERATION INTO RENTAL CAR OFFICE AND TUDOR SERVICE ACANTA MALL, TUN JOAQUIN SANTOS LANE AND PALE SAN VITORES ROAD
City
TAMUNING
State
GU
ZIP
96913
Mailing
PO BOX 9796, TAMUNING, GU 96931
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
11
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 3, 2015
Abate by
Aug 11, 2015
Penalty
Initial $1,020 · Current $600 Reduced
29 CFR 1926.20(b)(2): The employer failed to initiate and maintain programs that provided for frequent and regular inspections of the job sites, materials, and equipment by competent persons designated by the employer:    At the project, frequent and regular inspections of the job site, material and equipment were not made.  The Vice President of the employer said he was onsite that morning to drop off supplies, but he did not inspect the site to ensure it complied with OSHA regulations prior to leaving.  Employees were exposed to the hazards of contacting electricity and falling to the same level.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1020

1926.34 C

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 3, 2015
Abate by
Aug 11, 2015
Penalty
Initial $1,020 · Current $600 Reduced
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency:    Near the east side door from the interior to the exterior, the means of egress was not continually maintained free of obstructions and impediments as there were a compressor, electrical cords, air hoses, pieces of lumber, and plastic bags on the floor in the aisle to the door.  Employees were exposed to the hazard of fire and falling to the same level.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1020

1926.404 B01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 3, 2015
Abate by
Aug 11, 2015
Penalty
Initial $1,020 · Current $600 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  These requirements are in addition to any other requirements for equipment grounding conductors:    Near the east side exterior of the project, there were no ground-fault circuit-interrupters or an assured equipment grounding conductor program to protect employees that used a 110 VAC DeWalt miter saw to cut trim boards.  Power was supplied to the saw through a flexible cord plugged into a 110 VAC wall outlet.  The outlet was not a GFCI outlet.  Employees were exposed to the hazard of contacting electricity.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1020

1926.405 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 3, 2015
Abate by
Aug 11, 2015
Penalty
Initial $1,020 · Current $600 Reduced
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:    Inside the building on the first level, there was no cover on the 110 VAC outlet that supplied power through a flexible cord to a DeWalt miter saw used to cut trim boards.  The bottom of the 2 inch wide by 3.25 inch high outlet box was located 12 inches above the floor.  Employees were exposed to the hazards of contacting electricity.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1020

View Z Enterprises, INC.'s full OSHA safety record →