Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEORGE SALAS COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GEORGE SALAS COMPANY in RESTAURANT RENOVATION PROJECT CHALAN SAN ANTONIO, TAMUNING, GU 96913 (NAICS 236220). OSHA activity number 340729870.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch George Salas Company — free Get an email when a new federal OSHA severe-injury report for George Salas Company is published. One employer, no account, unsubscribe in one click.
Site address
RESTAURANT RENOVATION PROJECT CHALAN SAN ANTONIO
City
TAMUNING
State
GU
ZIP
96913
Mailing
214 ASSUMPTION DR., PITI, GU 96915
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
11
Ownership type
A

3 citations on file for this inspection.

1926.300 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 7, 2015
Abate by
Aug 17, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1926.300(b)(1): When power operated tools were designed to accommodate guards, they were not equipped with such guards when in use:  Inside the project, there was no guard on a 110 VAC Delta cut off saw used to cut metal studs.  The foreman said there was a guard on it at one time, but he did not know what happened to it.  Employees were exposed to the hazard of being struck by the abrasive cut of wheel.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1926.404 F07 IV C 5

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 7, 2015
Abate by
Aug 17, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1926.404(f)(7)(iv)(C)(5): Equipment connected by cord and plug. Under any of the conditions described in paragraphs (f)(7)(iv)(A) through (f)(7)(iv)(C) of this section, exposed noncurrent-carrying metal parts of cord- and plug-connected equipment, such as portable hand lamps, which may become energized was not grounded:  Inside the project, the metal shade on a 110 VAC temporary lamp was not grounded. The temporary lamp was clamped onto a metal mobile scaffold frame and was located about 56 inches above the floor. Employeees were exposed to the hazard of contacting electricity.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1926.405 A02 II J

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 7, 2015
Abate by
Aug 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(J): Flexible cords used with temporary and portable lights were not designed for hard or extra-hard usage:  Inside the project, the flexible cord to a 110 VAC temporary lamp was a two-wire zip cord not designed for hard or extra-hard useage. The temporary lamp was clamped onto a metal mobile scaffold frame and was located about 56 inches above the floor. Employeees were exposed to the hazard of contacting electricity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340729870.