Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACF INDUSTRIES LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACF INDUSTRIES LLC in 417 N. ARCH ST., MILTON, PA 17847 (NAICS 336510). OSHA activity number 340730092.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACF Industries LLC — free Get an email when a new federal OSHA severe-injury report for ACF Industries LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ACF INDUSTRIES LLC
Site address
417 N. ARCH ST.
City
MILTON
State
PA
ZIP
17847
Mailing
417 N. ARCH ST., MILTON, PA 17847
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336510
Employees
350
Ownership type
A

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 8, 2015
Abate by
Jan 27, 2016
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.22(a)(1): The employer does not have all places of employment, passageways, storerooms or service rooms kept clean and orderly or in a sanitary condition:  a) Blasting Area: Large quantities of dust (blasting material and scale) accumulated on building structures, floors and other surfaces, observed on or about 6/24/15.  Abatement Certification Required.
Recent events (3)
  • — F (S) $3000
  • — C (S) $3000
  • — Z (S) $3000

1910.332 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 8, 2015
Abate by
Jan 27, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.332(b)(1): The employer does not train employees in safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  a) Blasting Area: Employees were entering an energized electrical control cabinet in the blasting area to replace fuses without utilizing proper protective equipment or de-energizing the system, on or about 6/24/15.  Abatement Certification and Documentation Required
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.335 A01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 8, 2015
Abate by
Jan 27, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.335(a)(1)(i):  The employer does not provide employees working in areas where there are potential electrical hazards with electrical protective equipment that is appropriate for the specific parts of the body that need to be protected and for the work being performed:  a) Blasting Area: Employees were entering an energized 440 volt electrical control cabinet in the blasting area to replace fuses without wearing appropriate electrical protective equipment, on or about 6/24/15.  Abatement Certification and Documentation Required
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.333 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 8, 2015
Abate by
Jan 27, 2016
Penalty
Initial $70,000 · Current $7,000 Reduced
29 CFR 1910.333(a)(1): The employer does not have live parts de-energized before each employee works on or near them:    a) Blasting Area: Employees were entering an energized 440 volt electrical control cabinet in the blasting area to replace fuses and the employer did not ensure that all electrical systems and equipment has been de-energized and lockout/tagout applied, on or about 6/24/15.    Abatement Certification and Documentation is Required for this Violation.
Recent events (3)
  • — F (S) $7000
  • — C (W) $70000
  • — Z (W) $70000

View ACF Industries LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340730092.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.