OSHA Inspection: CMI GENERAL CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CMI GENERAL CONSTRUCTION in DINNER SHOW STRUCTURE DEMOLITION PROJECT FIESTA HOTEL, VILLAGE OF GARAPAN, SAIPAN, MP 96950 (NAICS 238910). OSHA activity number 340743855.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CMI General Construction — free Get an email when a new federal OSHA severe-injury report for CMI General Construction is published. One employer, no account, unsubscribe in one click.
Site address
DINNER SHOW STRUCTURE DEMOLITION PROJECT FIESTA HOTEL, VILLAGE OF GARAPAN
City
SAIPAN
State
MP
ZIP
96950
Mailing
P.O. BOX 502510 CK BEACH ROAD GARAPAN, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
11
Ownership type
A

4 citations on file for this inspection.

1926.416 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used:  Outside the project fence near an electric power pedestal, the outside insulation was worn down to the insulation on the wires on a flexible cord that provided 110 VAC power to the project.  Employees were exposed to the hazard of contacting electricity.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1926.25 A

Other-than-serious 1 instance 3 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, were not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:  Near the west side of the project, lumber with protruding nails were not kept cleared from the work areas and passageways, as nails protruded about 1.5 inches from 2 by 4 lumber that lay next to a flexible cord and in the passageways to the work areas at the site.  Employees were exposed to the hazard of striking against the nails.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.95 A

Other-than-serious 1 instance 3 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:  Near the west side of the project, eye protection was not worn when pounding 16 penny nails into lumber.  Eye protection was not available onsite.  Employees were exposed to the hazard of being struck in the eyes by the 16 penny nails.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.403 B02

Other-than-serious 1 instance 3 exposed
Issued
Jul 28, 2015
Abate by
Aug 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  At the project, a 4 by 4 inch square metal electrical box was not used as designed as it lay on the floor instead of being secured on a surface.  The boxes contained a 110 VAC electrical outlet that supplied power to a 110 VAC Makita reciprocating saw, model number JR 3050T, used to cut lumber.  Employees were exposed to the hazards of contacting electricity.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CMI General Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340743855.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.