Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BODINE ALUMINUM

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BODINE ALUMINUM in 100 CHERRY BLOSSOM WAY, TROY, MO 63379 (NAICS 336312). OSHA activity number 340744101.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bodine Aluminum — free Get an email when a new federal OSHA severe-injury report for Bodine Aluminum is published. One employer, no account, unsubscribe in one click.
Establishment
BODINE ALUMINUM
Site address
100 CHERRY BLOSSOM WAY
City
TROY
State
MO
ZIP
63379
Mailing
100 CHERRY BLOSSOM WAY, TROY, MO 63379
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336312
Employees
740
Ownership type
A

5 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 5 1 instance 40 exposed
Issued
Jul 2, 2015
Abate by
Aug 19, 2015
Penalty
Initial $4,250 · Current $2,125 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a. At the dust collector south location, airlock #2 south, was not locked out during maintenance.   Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $2125
  • — Z (S) $4250

1910.147 C04 II

Serious Gravity 5 1 instance 40 exposed
Issued
Jul 2, 2015
Abate by
Aug 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  a. A lockout specific operatring procedure was not written for the dust collector and associated equipment, airlock #2 south; energy sources included electrical to the fan/blower, electrical to the airlock, and pneumatic to the blow-down.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I C

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 2, 2015
Abate by
Aug 19, 2015
Penalty
Initial $4,250 · Current $2,125 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:  a. At least one maintenance employee's periodic review (defined as annual according to the OSHA directive) was last provided over 15 months before the time of the inspection.  b. There was no documentation for at least a second maintenance employee that a periodic review had been provided.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $2125
  • — Z (S) $4250

1910.303 F01

Serious Gravity 1 1 instance 40 exposed
Issued
Jul 2, 2015
Abate by
Aug 19, 2015
Penalty
Initial $2,550 · Current $2,125 Reduced
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a. The disconnect to airlock #2 south was not labeled to indicate its purpose.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $2125
  • — Z (S) $2550

1904.39 A02

Other-than-serious 1 instance 40 exposed
Issued
Jul 2, 2015
Penalty
Initial $1,000 · Current $500 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours.     a. An amputation that occurred on 6-26-15 was not reported until 6-29-15.
Recent events (2)
  • — I (O) $500
  • — Z (O) $1000

View Bodine Aluminum's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340744101.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.