WASHINGTON, DC —
OSHA Inspection: M & J CONTRACTORS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M & J CONTRACTORS LLC in 3441 14TH STREET NW, WASHINGTON, DC 20001 (NAICS 238130). OSHA activity number 340748169.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & J CONTRACTORS LLC
- Site address
- 3441 14TH STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20001
- Mailing
- 201 DAVIS DR, STERLING, VA 20164
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Nov 10, 2015
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units and the space between the platform and the uprights. a) On or about June 30, 2015; at the rear of the building or eastside, employees were observed working on a scaffold system that was not fully planked; the employees were exposed to a fall hazard of approximately 25-30 feet to ground level.
Recent events (1)
- — Z (S) $3080
1926.451 G01 VII
- Issued
- Nov 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about June 30, 2015; at the rear or eastside of the building, employees were observed working on a scaffold system without fall protection in place to prevent them from falling an estimated 25-30 feet to ground level.
Recent events (1)
- — Z (S) $0
1926.1052 C01 II
- Issued
- Nov 10, 2015
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) On or about June 30, 2015; rear of building or eastside, employees were using stairs in which the risers were not guarded exposing employees to falls greater than 6-30 feet to ground level.
Recent events (1)
- — Z (S) $3080
1926.1052 C12
- Issued
- Nov 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a) On or about June 30, 2015; rear of building or eastside, employees were exposed to a fall hazard while working or accessing the landings on the stairway; employees were exposed to fall hazards of 6 - 30 feet.
Recent events (1)
- — Z (S) $0
1926.405 G02 IV
- Issued
- Nov 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) On or about June 30, 2015; rear of the building or eastside, employees were operating electrical equipment, such as but not limited to, portable circular saws that were plugged into a portable extension cord of which the strain relief was damaged, exposing the inner wires.
Recent events (1)
- — Z (O) $0
1926.404 B01 II
- Issued
- Nov 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) On or about 30, 2015; rear of the building or eastside, employees were operating a portable circular saw that was not plugged into a ground fault circuit interrupter.
Recent events (1)
- — Z (O) $0
More inspections at M & J Contractors LLC
View M & J Contractors LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340748169.