WASHINGTON, DC —
OSHA Inspection: M & J CONTRACTORS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M & J CONTRACTORS LLC in 2812 38TH STREET NW, WASHINGTON, DC 20010 (NAICS 238160). OSHA activity number 341526002.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & J CONTRACTORS LLC
- Site address
- 2812 38TH STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- 201 DAVIS DRIVE SUITE S, STERLING, VA 20164
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E01
- Issued
- Jul 22, 2016
- Abate by
- Aug 1, 2016
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about April 26, 2016; front of residential home; employees were accessing a ladder-jack scaffold by the inner ladders located at the ends of the scaffold system; exposing them to a fall of 27 feet while reaching for the rungs or working platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3080
1926.451 F07
- Issued
- Jul 22, 2016
- Abate by
- Aug 1, 2016
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) On or about April 26, 2016; front of residential home; the employer did not have a trained competent person on site to properly understand the requirements of a ladder-jack system such as but not limited the height restriction and fall protection needs. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3080
1926.452 K01
- Issued
- Jul 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m) a) On or about April 26, 2016; front of residential home; the employer had erected a ladder-jack scaffold, 27 feet to ground level, to install the shingles on 11:12 pitch roof. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.451 G01 I
- Issued
- Jul 22, 2016
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about April 26, 2016; front of residential home; employees working on a ladder-jack scaffold were not protected from falling 27 feet to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3080
More inspections at M & J Contractors LLC
View M & J Contractors LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341526002.