OSHKOSH, WI —
OSHA Inspection: IHDE BUILDERS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of IHDE BUILDERS in ELK RIDGE DR. AND RUFFED GROUSE WAY, OSHKOSH, WI 54904 (NAICS 236116). OSHA activity number 340753250.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IHDE BUILDERS
- Site address
- ELK RIDGE DR. AND RUFFED GROUSE WAY
- City
- OSHKOSH
- State
- WI
- ZIP
- 54904
- Mailing
- 2310 STROEBE ISLAND DRIVE, APPLETON, WI 54914
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 15, 2015
- Abate by
- Oct 12, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 07-06-15, employees were installing residential roof sheathing on an approximately 5:12 pitch roof with an eave edge approximately 8.5 feet above surface level without utilizing fall protection equipment.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.503 A02 VIII
- Issued
- Sep 15, 2015
- Abate by
- Oct 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M: a) On or about 07-06-15, five employees were exposed to fall hazards without receiving adequate training in the standards of subpart M. Employees were not utilizing fall protection equipment when working on roof surfaces of a building with 8 ft. side walls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 B01
- Issued
- Sep 15, 2015
- Abate by
- Oct 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) Employer did not provide written certification of required fall protection safety training for employees working at heights greater than six (6) feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B04
- Issued
- Sep 15, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about 07-06-15, employees were utilizing two 8 ft. stepladders to access/egress a roof surface at approximately 8.5 ft. above surface level without opening the ladders into a locked, stable position. Each ladder was folded with the top of the ladder leaning against an interior wall.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.1053 B18
- Issued
- Sep 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(18): Ladder repairs did not restore the ladder to a condition meeting its original design criteria before the ladder was returned to use: a. On or about July 6, 2015, employees were using a wooden stepladder that had the cap replaced and repaired with OSB plywood. The plywood did not meet the requirements of restoring the ladder to the original design specifications.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Ihde Builders
View Ihde Builders's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340753250.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.