Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FUZION TECHNOLOGIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FUZION TECHNOLOGIES, INC. in 500 MILL STREET, FREEPORT, PA 16229 (NAICS 327124). OSHA activity number 340759273.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fuzion Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Fuzion Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
500 MILL STREET
City
FREEPORT
State
PA
ZIP
16229
Mailing
P.O. BOX 338, FREEPORT, PA 16229
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327124
Employees
58
Ownership type
A

6 citations on file for this inspection.

1910.215 A01

Serious Gravity 1 2 instances 1 exposed
Issued
Sep 25, 2015
Abate by
Oct 7, 2015
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):      a)  Press area, 500 Mill Street, Freeport, PA 16229:  Observed on or about June 29, 2015, the right abrasive wheel on a Dewalt DW758 bench grinder was not equipped with a tongue guard.  A gap of approximately 1 and 1/8 inches existed between the right grinding wheel and the frame of the machine.  Employees using the bench grinder where exposed to struck-by and fire hazards while using the bench grinder.                                                        b)  Press area, 500 Mill Street, Freeport, PA 16229:  Observed on or about June 29, 2015, the left abrasive wheel on a Dewalt DW758 bench grinder was not equipped with a tongue guard.  A gap of approximately 1 and 1/2 inches existed between the left grinding wheel and the frame of the machine.  Employees using the bench grinder where exposed to struck-by and fire hazards while operating the bench grinder.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.215 A04

Serious Gravity 1 2 instances 1 exposed
Issued
Sep 25, 2015
Abate by
Oct 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4):  Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   a)  Press area, 500 Mill Street, Freeport, PA 16229:  Observed on or about June 29, 2015, the work rest on the left wheel of a Dewalt DW758 bench grinder was not adjusted such that the maximum opening between the abrasive wheel and the work rest was not more than 1/8 of an inch.  The gap between the abrasive wheel and the work rest was approximately 3/4 of an inch.  Employees using the bench grinder were exposed to caught-by hazards.  b)  Press area, 500 Mill Street, Freeport, PA 16229:  Observed on or about June 29, 2015, the work rest on the right wheel of a Dewalt DW758 bench grinder was not adjusted such that the maximum opening between the abrasive wheel and the work rest was not more than 1/8 of an inch.  The gap between the abrasive wheel and the work rest was approximately 7/16 of an inch.  Employees using the bench grinder were exposed to caught-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 25, 2015
Abate by
Nov 2, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(7)(i)(A):  Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:       a)  Press area, 500 Mill Street, Freeport, PA 16229:  Observed on or about June 29 2015,  the employer did not ensure that each employee engaged in the maintenance of mechanical power presses were trained as authorized employees under the employer's energy control program.  Employees who were not trained as authorized employees under the employer's energy control program were assigned maintenance tasks, including die changes, on the #1, #3, and Y presses.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 F03 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 25, 2015
Abate by
Nov 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department, or other group:           a)  Press area, 500 Mill Street, Freeport, PA 16229:  Observed on or about June 29, 2015, the employer did not ensure that procedures were utilized that afforded each employee a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when crews consisting of more than one employee changed the press dies and/or performed other maintenance work on each of the three dry presses.  The employees were exposed to crushed-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii):  Working space about electric equipment rated 600 volts, nominal, or less was used for storage:   a) Binding area, 500 Mill Street, Freeport, PA 16229:  Observed on or about June 29, 2015, the working space in front of electrical equipment (480 volt, 3 phase) located on a wall in the binding area was used storage.  A table, boxes, and a fan were stored in front of the electrical equipment.  Employees working in the main shop were exposed to fire and electric shock hazards created by restricted access to the electrical panels.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2015
Abate by
Oct 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:   a)  Press area, 500 Mill Street, Freeport, PA 16229:  Observed on or about September 02, 2015, unused openings on the side and on the front cover of a Square D brand distribution panel (120/240 volt) labeled 'PO-2" were not effectively closed.  The openings could permit the accumulation of dust and debris inside the cabinet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fuzion Technologies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340759273.