OSHA Inspection: SCHWANS GLOBAL SUPPLY CHAIN, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of SCHWANS GLOBAL SUPPLY CHAIN, INC. in ONE LEMON LANE, ATLANTA, GA 30307 (NAICS 311813). OSHA activity number 340780899.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schwans Global Supply Chain, INC. — free Get an email when a new federal OSHA severe-injury report for Schwans Global Supply Chain, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ONE LEMON LANE
City
ATLANTA
State
GA
ZIP
30307
Mailing
ONE LEMON LANE, ATLANTA, GA 30307
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311813
Employees
356
Ownership type
A

2 citations on file for this inspection.

1910.120 Q08 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2016
Abate by
Mar 4, 2016
Penalty
Initial $4,675 · Current $4,675

Hazardous substances 0170

29 CFR 1910.120(q)(8)(i): Employees who were trained in accordance with 29 CFR 1910.120(q)(6) did not receive annual refresher training of sufficient content and duration to maintain their competencies or did not demonstrate competency in those areas at least yearly:  Schwan's Global Supply Chain, Inc., Atlanta, GA - Refrigeration technicians were assigned and expected to respond to an ammonia leak as a first responder operations level. A refresher training had not been conducted since May 2014, on or about 7/15/15.
Recent events (2)
  • — I (S) $4675
  • — Z (S) $4675

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Jan 15, 2016
Abate by
Feb 11, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 0170

29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  Schwans Global Supply Chain, Inc., Atlanta, GA - A Refrigeration Technician and a Waste Water Technician were assigned and expected to use of full face respirator for protection against ammonia. The employees were fit tested in May 2014. Annual fit test for year 2015 had not been performed, on or about 7/15/15.