OSHA Inspection: VA WESTERN NY HEALTHCARE SYSTEM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VA WESTERN NY HEALTHCARE SYSTEM in 3495 BAILEY AVENUE, BUFFALO, NY 14215 (NAICS 622110). OSHA activity number 340797661.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VA Western NY Healthcare System — free Get an email when a new federal OSHA severe-injury report for VA Western NY Healthcare System is published. One employer, no account, unsubscribe in one click.
Site address
3495 BAILEY AVENUE
City
BUFFALO
State
NY
ZIP
14215
Mailing
3495 BAILEY AVENUE, BUFFALO, NY 14215
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
1976
Ownership type
D

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 10 exposed
Issued
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, were not kept clean and orderly, or in a sanitary condition:  a) On or about 6/22/15, in the subbasement (B wing) left of room S16, employer failed to provide a work environment clean and orderly and in a sanitary condition exposing employees to tripping hazards due to excessive accumulation debris and materials being stored in the hallway.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.36 A03

Serious Gravity 5 2 instances 10 exposed
Issued
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(a)(3): An opening into an exit was not protected by a self-closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a nationally recognized testing laboratory. Section 1910.155(c)(3)(iv)(A) of this part defines "listed" and � 1910.7 of this part defines a "nationally recognized testing laboratory."  a) On or about 6/22/15, in Room S15 (Electrical Room), where the exit door was not self-closing, employees were exposed to fire hazards in case of an emergency. b) On or about 6/22/15, in Room S18 (Trash Room), where exit door was not self-closing, employees were exposed to fire hazards in case of an emergency.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure  a) On or about, 6/22/15, in the Chemistry Department (B Wing), employer failed to protect employees by using flexible cords as a substitute for permanent wiring, to plug in a power strip used to energize fans, potentially exposing employees to electrical shocks.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 15 exposed
Issued
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) On or about 06/22/15, in Kitchen (Basement-A Wing), the electrical outlet 208-B #5 located to the right to the kitchen sink, used to power kitchen appliances, did not have a Ground-Fault Circuit-Interrupter as required by the National Electric Code (2014, section 422.52).  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.147 C06 II

Other-than-serious 1 instance 10 exposed
Issued
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection.  a) On or about 06/22/15, in the Plumbing/ A/C department, employer failed to provide periodic inspection certification of the Lockout/Tagout procedure for machines such as  but not limited to, Floor band saw, Bench grinder and magnetic drill.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (O) $0

View VA Western NY Healthcare System's full OSHA safety record →