AKRON, OH —
OSHA Inspection: RUSSELL PRODUCTS CO INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of RUSSELL PRODUCTS CO INC. in 1066 HOME AVE, AKRON, OH 44310 (NAICS 332812). OSHA activity number 340798396.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUSSELL PRODUCTS CO INC.
- Site address
- 1066 HOME AVE
- City
- AKRON
- State
- OH
- ZIP
- 44310
- Mailing
- 1066 HOME AVE, AKRON, OH 44310
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.95 B01
- Issued
- Aug 31, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized: On August 25, 2015, the shot blaster was exposed to continuous noise levels at 247% of the permissible daily exposure (8-hour, time-weighted average sound level of 90 dbA or equivalently, a dose of 100 percent), during the 438 minute sampling period. Exposure calculations include a zero increment for the 42 minutes not sampled. 96.52 dBA
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 A02 IX
- Issued
- Aug 31, 2015
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: On or about July 24, 2015, the employer did not have a fluorescent light bulb in the spray booth area that was exposed to combustible dust covered with a suitable guard. The guard had been broken and not replaced.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.134 C01 VI
- Issued
- Aug 31, 2015
- Abate by
- Sep 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1)(vi): The written program did not contain procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators: On or about July 24, 2015, the employer did not have procedures in the written respiratory protection program that ensured the supplied air respirator hooked to an air compressor was supplying adequate grade D air.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Russell Products CO INC.
View Russell Products CO INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340798396.