Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HOAG ROOFING

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of HOAG ROOFING in NPS HOUSING UNIT, CRATER LAKE, OR 97604 (NAICS 238160). OSHA activity number 340802040.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hoag Roofing — free Get an email when a new federal OSHA severe-injury report for Hoag Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
HOAG ROOFING
Site address
NPS HOUSING UNIT
City
CRATER LAKE
State
OR
ZIP
97604
Mailing
842 ENTERPRISE DR, CENTRAL POINT, OR 97502
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.502 D06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 1, 2015
Abate by
Sep 8, 2015
Penalty
Initial $1,700 · Current $1,700
29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself.  (a) Located on the Community Center roof at the Steele Center Compound in Crater Lake National Park, an employee patching the roof secured his rope lanyard to a vertical pipe by wrapping the rope around the pipe and hooking his snaphook back to the rope lanyard. The snaphook was not designed for this application, potentially exposing employees to death from failure of the system if they were to fall to the lower level of about 24 feet.
Recent events (1)
  • — Z (S) $1700

1926.502 D15

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 1, 2015
Abate by
Sep 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.   (a) Located on the Community Center roof at the Steele Center Compound in Crater Lake National Park, employees patching the roof used a piece of vertical pipe protruding from the roof as an anchor point. The configuration of the pipe did not allow for a means to prevent disengagement of the personal fall arrest system in the event that fall were to occur, potentially exposing employees to death from a fall to the lower level of about 24 feet.
Recent events (1)
  • — Z (S) $0

View Hoag Roofing's full OSHA safety record →