CRATER LAKE, OR —
OSHA Inspection: HOAG ROOFING
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HOAG ROOFING in NPS HOUSING UNIT, CRATER LAKE, OR 97604 (NAICS 238160). OSHA activity number 340802040.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOAG ROOFING
- Site address
- NPS HOUSING UNIT
- City
- CRATER LAKE
- State
- OR
- ZIP
- 97604
- Mailing
- 842 ENTERPRISE DR, CENTRAL POINT, OR 97502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 D06 I
- Issued
- Sep 1, 2015
- Abate by
- Sep 8, 2015
- Penalty
- Initial $1,700 · Current $1,700
General-duty citation text
29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. (a) Located on the Community Center roof at the Steele Center Compound in Crater Lake National Park, an employee patching the roof secured his rope lanyard to a vertical pipe by wrapping the rope around the pipe and hooking his snaphook back to the rope lanyard. The snaphook was not designed for this application, potentially exposing employees to death from failure of the system if they were to fall to the lower level of about 24 feet.
Recent events (1)
- — Z (S) $1700
1926.502 D15
- Issued
- Sep 1, 2015
- Abate by
- Sep 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. (a) Located on the Community Center roof at the Steele Center Compound in Crater Lake National Park, employees patching the roof used a piece of vertical pipe protruding from the roof as an anchor point. The configuration of the pipe did not allow for a means to prevent disengagement of the personal fall arrest system in the event that fall were to occur, potentially exposing employees to death from a fall to the lower level of about 24 feet.
Recent events (1)
- — Z (S) $0
More inspections at Hoag Roofing
View Hoag Roofing's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340802040.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.