JAMESTOWN, NY —
OSHA Inspection: ANDERSON PRECISION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANDERSON PRECISION, INC. in 20 LIVINGSTON AVENUE, JAMESTOWN, NY 14701 (NAICS 332721). OSHA activity number 340839638.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANDERSON PRECISION, INC.
- Site address
- 20 LIVINGSTON AVENUE
- City
- JAMESTOWN
- State
- NY
- ZIP
- 14701
- Mailing
- 20 LIVINGSTON AVENUE, JAMESTOWN, NY 14701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 105
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 B07
- Issued
- Aug 19, 2015
- Abate by
- Aug 21, 2015
- Penalty
- Initial $2,025 · Current $1,519 Reduced
General-duty citation text
29 CFR 1910.303(b)(7): 29 CFR 1910.303(b)(7): Electrical equipment was not installed in a neat and workmanlike manner: a) On or about 08/18/2015 in the machining area; where wire energizing the stepping motor (from overhead) on screw machine #130 were in contact with the edge of the overhead light fixture causing abrasion of the outer insulation of the wire. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1518.75
- — Z (S) $2025
1910.335 A01 II
- Issued
- Aug 19, 2015
- Abate by
- Sep 11, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment was not periodically inspected or tested as required by 1910.137: a) On or about 08/18/2015 in maintenance; where electrical protective gloves were last inspected in January, 2015. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Anderson Precision, INC.
View Anderson Precision, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332721)
More inspections in NY
Source