SUSSEX, WI —
OSHA Inspection: THE PRESTWICK GROUP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE PRESTWICK GROUP, INC. in W248 N5499 EXECUTIVE DRIVE, SUSSEX, WI 53089 (NAICS 326199). OSHA activity number 340849223.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE PRESTWICK GROUP, INC.
- Site address
- W248 N5499 EXECUTIVE DRIVE
- City
- SUSSEX
- State
- WI
- ZIP
- 53089
- Mailing
- W248 N5499 EXECUTIVE DRIVE, SUSSEX, WI 53089
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 115
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Jan 19, 2016
- Penalty
- Initial $6,930 · Current $3,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Delta Table Saw - Machine No. 33: Employees were exposed to an amputation hazard while working on a Delta table saw. The employer did not ensure the point of operation was guarded properly in-that the guard was placed in an upright position allowing the employees hand to access the blade.
Recent events (2)
- — I (S) $3400
- — Z (S) $6930
1910.147 C06 II
- Issued
- Jan 19, 2016
- Abate by
- Feb 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection. (a) The periodic inspection of the energy control procedure(s) did not identify the equipment or machine evaluated, employee observed performing the lockout procedure and the person conducting the periodic inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at The Prestwick Group, INC.
View The Prestwick Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340849223.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.