SUSSEX, WI —
OSHA Inspection: THE PRESTWICK GROUP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE PRESTWICK GROUP, INC. in W248 N5499 EXECUTIVE DRIVE, SUSSEX, WI 53089 (NAICS 326199). OSHA activity number 345141188.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE PRESTWICK GROUP, INC.
- Site address
- W248 N5499 EXECUTIVE DRIVE
- City
- SUSSEX
- State
- WI
- ZIP
- 53089
- Mailing
- W248 N5499 EXECUTIVE DRIVE, SUSSEX, WI 53089
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 130
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- May 27, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $8,953 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 1 Komo Xtreme CNC router machine. Elements of the machine including, but not limited to, the travel area of the material table, were not guarded, exposing workers to struck-by hazards. (b) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 3 Komo Xtreme CNC router machine. Elements of the machine including, but not limited to, the travel area of the material table, were not guarded, exposing workers to struck-by hazards. (c) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 4 Komo Xtreme CNC router machine. Elements of the machine including, but not limited to, the travel area of the material table, were not guarded, exposing workers to struck-by hazards. (d) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 1 MultiCam 5000 CNC router machine. Elements of the machine including, but not limited to, the support structure of the cutter head, were not guarded, exposing workers to struck-by hazards. (e) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 2 MultiCam 5000 CNC router machine. Elements of the machine including, but not limited to, the support structure of the cutter head, were not guarded, exposing workers to struck-by hazards. (f) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 3 MultiCam 5000 CNC router machine. Elements of the machine including, but not limited to, the support structure of the cutter head, were not guarded, exposing workers to struck-by hazards. (g) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 4 MultiCam 5000 CNC router machine. Elements of the machine including, but not limited to, the support structure of the cutter head, were not guarded, exposing workers to struck-by hazards. (h) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure adequate guarding was implemented on the # 5 MultiCam 5000 CNC router machine. Elements of the machine including, but not limited to, the support structure of the cutter head, were not guarded, exposing workers to struck-by hazards. (i) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure a Jet drill press machine was adequately guarded, thereby exposing workers to entanglement hazards. (j) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure a Delta drill press machine was adequately guarded, thereby exposing workers to entanglement hazards.
Recent events (3)
- — F (S) $3500
- — C (S) $8953
- — Z (S) $8953
1910.212 A02
- Issued
- May 27, 2021
- Abate by
- Jun 23, 2021
- Penalty
- Initial $4,476 · Current $500 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: (a) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure the guard on the Kreg 5 Hole Pocket Drill was adequately secured. The guard, which consisted of a cover, was loose and was not fixed to the machine, exposing employees to laceration injuries.
Recent events (3)
- — F (S) $500
- — C (S) $4476
- — Z (S) $4476
1910.147 C06 II
- Issued
- May 27, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: (a) On or about February 9, 2021, at the worksite located at W248 N5499 Executive Dr., Sussex, WI, the employer did not ensure periodic inspection of energy control procedures included information including, but not limited to, employees included in the review and identification of machines or equipment.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at The Prestwick Group, INC.
View The Prestwick Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345141188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.