Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STERLING PRODUCTS CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STERLING PRODUCTS CORP. in 90 DAYTON AVE., PASSAIC, NJ 07055 (NAICS 335121). OSHA activity number 340850684.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sterling Products Corp. — free Get an email when a new federal OSHA severe-injury report for Sterling Products Corp. is published. One employer, no account, unsubscribe in one click.
Site address
90 DAYTON AVE.
City
PASSAIC
State
NJ
ZIP
07055
Mailing
90 DAYTON AVE., PASSAIC, NJ 07055
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335121
Employees
21
Ownership type
A

15 citations on file for this inspection.

1910.37 B04

Serious Gravity 5 2 instances 20 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:      a) Basement- Hallway: Employees did not have a clear indication of the direction of travel to exit the building in an emergency, on or about 8/13/2015.    b) 2nd Floor- Back Wall: Employees did not have a clear indication of the direction of travel to exit the building in an emergency, on or about 8/13/2015.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.37 B05

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):      a) Basement- Hallway: Employees were exposed to disorientation in case of an emergency as a door into the basement storage area was not marked "Not an Exit"  , on or about 8/13/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.38 B

Serious Gravity 5 1 instance 20 exposed
Issued
Dec 4, 2015
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:      a) At Sterling Products Corp.: The employer of 20 employees did not have a written emergency action plan for fire or other emergencies in the workplace, on or about 8/13/2015.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.110 E04 III

Other-than-serious 1 instance 1 exposed
Issued
Dec 4, 2015
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating:    a) 1st Floor - Packaging  area: Propane tank being used to fuel PIT was not secured in place by the index pin, on or about 8/13/2015.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

1910.110 F02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize physical damage, or tampering from unauthorized persons:   a) 1st Floor - Packaging  area: Compressed gas cylinders containing propane were unsecured and stored next to storage rack, on or about 8/13/2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.178 L06

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 4, 2015
Penalty
Initial $2,000 · Current $720 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):    a) 1st Floor - Packaging  area: The operator of a Propane fueled PIT had not been certified by the employer as trained, on or about 8/13/2015.
Recent events (2)
  • — I (S) $720
  • — Z (S) $2000

1910.212 A03 II

Serious Gravity 10 2 instances 5 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefore, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his/her body in the danger zone during the operating cycle.    a) 1st Floor - Cutting area: Employee was exposed to amputation hazards while engaged in acrylic cutting operations utilizing a table saw that was not provided with any guard, on or about 8/13/2015.    b) 2nd Floor - Cutting area: Employee was exposed to amputation hazards while engaged in acrylic cutting operations utilizing a band saw that was not provided with any guard, on or about 8/13/2015.    c) 2nd Floor - Cutting area: Employee was exposed to amputation hazards while engaged in acrylic cutting operations utilizing a router that was not provided with any guard, on or about 8/13/2015.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.213 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 4, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:      a) Basement- Cutting area: Employee was exposed to amputation hazards while engaged in wood cutting operations utilizing a table saw that was guarded, on or about 8/13/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.213 M01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.213(m)(1): Cutting heads of wood shaper(s) were not enclosed with a cage or adjustable guard so designed so as to keep the operator's hand away from the cutting edge:      a) Basement- Cutting area: Employee was exposed to amputation hazards while engaged in wood cutting operations utilizing a fixed router that was not guarded, on or about 8/13/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.242 B

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 4, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) 2nd Floor - Hydraulic Press area: Employees were exposed to struck by hazards while engaged in cleaning activities using a compressed air nozzle that was putting out 40 Lbs of pressure, on or about 8/13/2015.   b) 3rd Floor - Cleaning area: Employees were exposed to struck by hazards while engaged in cleaning activities using a compressed air nozzle that was putting out 50 Lbs of pressure, on or about 8/13/2015.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.303 G01 II

Serious Gravity 5 2 instances 4 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) 1st  Floor - Packaging Are - Electric Panel: The electric breakers that controlled the lights as well as motors were in an electric panel that was blocked by 55 Gl Drum of Alcohol, on or about, 8/13/2015.  b) 1st Floor - Cutting Area: The electric breakers that controlled the motors were in an electric panel that was blocked by a shelving system, on or about 10/8/2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.304 G05

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 4, 2015
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   a) 3rd Floor: The ground pin was missing on the buffer machine, on or about, 10/8/2015.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.305 B01 II

Serious Gravity 5 4 instances 5 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   a) 2nd Floor - Electric Panel: The electric panel used to control the equipment and light fixtures on the floor had openings, on or about, 8/13/2015.  b) 1st  Floor - Packaging Area - Electric Panel: The electric junction box was missing the cover plate, on or about, 8/13/2015.  c) 2nd Floor - Big Oven: The electric junction box had an open cover plate, on or about, 10/8/2015.  d) 2nd Floor - Hydraulic Press # 15: The electric junction box had unused openings, on or about, 10/8/2015.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 G01 IV D

Other-than-serious 1 instance 4 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:      a) 1st Floor - Packaging  area: A Relocatable Power Tap electric cord was attached with metal staples onto the plywood backboard, on or about 10/8/2015.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

1910.305 G02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 4, 2015
Abate by
Dec 24, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:   a) 2nd Floor - Hydraulic Press: The flexible electrical cord on a  Hydraulic Press was spliced and not used in continuous lengths, on or about, 8/13/2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

View Sterling Products Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340850684.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.