Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CROTHALL LAUNDRY SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CROTHALL LAUNDRY SERVICES, INC. in 9905 S. 13TH ST., OAK CREEK, WI 53154 (NAICS 812320). OSHA activity number 340854413.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crothall Laundry Services, INC. — free Get an email when a new federal OSHA severe-injury report for Crothall Laundry Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9905 S. 13TH ST.
City
OAK CREEK
State
WI
ZIP
53154
Mailing
9905 S. 13TH ST., OAK CREEK, WI 53154
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
260
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2016
Abate by
Feb 16, 2016
Penalty
Initial $6,600 · Current $6,600
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards while using a step ladder to access and egress an elevated conveyor.     In the Milnor dryer area, employees used a Keller fiberglass step ladder to gain access to the Pellerin Milnor conveyor at the #11 Milnor dryer location to perform maintenance work on the dryer. The employee climbed over the conveyor side shield that was approximately 27-inches high and was exposed to a fall hazard of over 8-feet to the concrete floor below.
Recent events (1)
  • — Z (S) $6600

1910.132 A

Serious Gravity 5 2 instances 1 exposed
Issued
Feb 9, 2016
Abate by
Feb 16, 2016
Penalty
Initial $6,600 · Current $6,600
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  (a) On or about August 13, 2015, in the Milnor dryer area, on the conveyor between Dryer # 11 and Dryer # 5, an employee was standing on an 8-foot high conveyor belt near the edge without being protected by a railing system or equivalent type of fall protection.   (b) On or about August 11, 2015, in the Milnor dryer area, on the conveyor between Dryer # 11 and Dryer # 5, an employee was standing on an 8-foot high conveyor belt near the edge without being protected by a railing system or equivalent type of fall protection.
Recent events (1)
  • — Z (S) $6600

1910.147 C04 II

Serious Gravity 10 2 instances 5 exposed
Issued
Feb 9, 2016
Abate by
Mar 28, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:   (a) The employer did not ensure that specific procedures such as, but not limited to, rules, techniques, and purpose were developed for the control of hazardous energy for equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 13, 2015, an employee was propelled into an industrial dryer when the conveyor system activated. The dryer subsequently activated with the employee trapped inside.   (b) The employer did not ensure that specific procedures such as, but not limited to, rules, techniques, and purpose were developed for the control of hazardous energy for equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 11, 2015, an employee was conducting maintenance work without using proper hazardous energy control procedures.
Recent events (1)
  • — Z (S) $7000

1910.147 C06 I

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 9, 2016
Abate by
Mar 28, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   (a) The employer did not ensure that a periodic inspection of the hazardous energy control procedures was conducted on equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor.
Recent events (1)
  • — Z (S) $7000

1910.147 C07 I A

Serious Gravity 10 2 instances 5 exposed
Issued
Feb 9, 2016
Abate by
Mar 28, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:   (a) The employer did not ensure that authorized employees had received training in the methods and means necessary for energy isolation for equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 13, 2015, an employee was propelled into an industrial dryer when the conveyor system activated. The dryer subsequently activated with the employee trapped inside.  (b) The employer did not ensure that authorized employees had received training in the methods and means necessary for energy isolation for equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 11, 2015, an employee was conducting maintenance work without using proper hazardous energy control procedures.
Recent events (1)
  • — Z (S) $7000

1910.147 D03

Serious Gravity 10 2 instances 5 exposed
Issued
Feb 9, 2016
Abate by
Feb 16, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) The employer did not ensure that energy isolating devices that are needed for the control of hazardous energy were utilized on equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 13, 2015, an employee was propelled into an industrial dryer when the conveyor system activated. The dryer subsequently activated with the employee trapped inside.  (b) The employer did not ensure that energy isolating devices that are needed for the control of hazardous energy were utilized on equipment such as, but not limited to, the Milnor dryer and Pellerin Milnor conveyor. On or about August 11, 2015, an employee was conducting maintenance work and was not using the proper hazardous energy control devices.
Recent events (1)
  • — Z (S) $7000