ERIE, PA —
OSHA Inspection: F & S TOOL, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of F & S TOOL, INC. in 2300 POWELL AVENUE, ERIE, PA 16506 (NAICS 333514). OSHA activity number 340855113.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- F & S TOOL, INC.
- Site address
- 2300 POWELL AVENUE
- City
- ERIE
- State
- PA
- ZIP
- 16506
- Mailing
- 2300 POWELL AVENUE, ERIE, PA 16506
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333514
- Employees
- 70
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 7, 2016
- Abate by
- Jul 18, 2016
- Penalty
- Initial $4,410 · Current $3,500 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Employees were potentially exposed to fire and explosion hazards from dust collectors located inside the building. Dust collectors included, but not limited to, the Torit SDF 6 (Serial #: IG394319-001) were located inside the building, and were not equipped with devices to mitigate a potential dust explosion. The dust collector collected dusts from materials including, but not limited to, aluminum oxide and stainless steel. B.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Employees were potentially exposed to fire and explosion hazards from dust collectors that were not equipped with devices and systems to prevent the propagation of explosions and associated flame fronts from the dust collector through the associated dust collection system duct work. Dust collection systems including, but not limited to, the Torit SDF 6 (Serial #: IG394319-001) was not equipped with approved devices to prevent the propagation of a dust explosion and associated flame fronts throughout the dust collection system and the associated duct work. The dust collector collected dusts from materials including, but not limited to, aluminum oxide and stainless steel. C.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Employees were potentially exposed to fire and explosion hazards from dust collectors located outside the building near an employee break area. Dust collectors included, but not limited to, the Torit DFT2-8 (Serial #: IG363057-001) were located outside the building near the employee break area, and were not equipped with devices to mitigate a potential dust explosion. The dust collector collected dusts from materials including, but not limited to, aluminum oxide and stainless steel. D.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Employees were potentially exposed to fire and explosion hazards from dust collectors that were not equipped with devices and systems to prevent the propagation of explosions and associated flame fronts from the dust collector through the associated dust collection system duct work. Dust collection systems including, but not limited to, the Torit DFT2-8 (Serial #: IG363057-001) was not equipped with approved devices to prevent the propagation of a dust explosion and associated flame fronts throughout the dust collection system and the associated duct work. The dust collector collected dusts from materials including, but not limited to, aluminum oxide and stainless steel.
Recent events (2)
- — I (S) $3500
- — Z (S) $4410
1910.24 H
- Issued
- Jan 7, 2016
- Abate by
- Feb 3, 2016
- Penalty
- Initial $1,890 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about November 9, 2015 and times prior thereto: A set of wooden fixed industrial stairs was used to access a platform that contained equipment including, but not limited to, an air compressor unit. The fixed industrial stair contained 15 risers, and was not equipped with a standard hand / guard rail on the left side of the stairs.
Recent events (2)
- — I (S) $1400
- — Z (S) $1890
1910.157 C01
- Issued
- Jan 7, 2016
- Abate by
- Feb 3, 2016
- Penalty
- Initial $1,890 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Items including, but not limited to, wood tubing fixture racking were stored in front of the Kidde dry chemical fire extinguisher (M/N: K10M, S/N: WG-899221).
Recent events (2)
- — I (S) $1000
- — Z (S) $1890
1910.157 E02
- Issued
- Jan 7, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Fire extinguishers including, but not limited to, the Kidde dry chemical fire extinguisher (M/N: K10M, S/N: WG-899221) were not inspected on a monthly basis.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Jan 7, 2016
- Abate by
- Feb 3, 2016
- Penalty
- Initial $2,520 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about November 9, 2015 and times prior thereto: Employees utilize a removable rotating fixture on the Okamoto Linear Grinder (Model 6 - 12/14) to perform tasks including, but not limited to, grinding grooves into bushings. The flexible electrical cord for the removable rotating fixture was frayed.
Recent events (2)
- — I (S) $1000
- — Z (S) $2520
1904.29 B01
- Issued
- Jan 7, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $630 · Current $0 Reduced
General-duty citation text
29 CFR 1904.29(b)(1): The employer did not provide the required injury or illness descriptions on the Log of Work-Related Injuries and Illnesses, OSHA Form 300: A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Column F for case #2 on the 2015 OSHA Form 300 Log of Work-Related Injuries and Illnesses does not contain information including, but not limited to, the object/substance that directly injured the employee.
Recent events (2)
- — I (O) $0
- — Z (O) $630
1910.138 A
- Issued
- Jan 7, 2016
- Abate by
- Feb 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about August 18, 2015 and times prior thereto: Employees utilize chemicals including, but not limited to, Sunnyside Acetone to clean parts. The company does not require the use of hand protection when handling / using the chemical.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Jan 7, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: A.) F & S Tool, Inc., 2300 Powell Avenue, Erie, PA 16506, on or about October 30, 2015 and times prior thereto: Employees utilize chemicals including, but not limited to, Sunnyside Acetone to clean parts. The companys written hazard communication program is lacking elements including, but not limited to: 1.) Procedures to follow if it is suspected that the safety data sheet for a chemical is not appropriate, 2.) Procedures to follow to determine if the safety data sheet for a chemical is current, and 3.) How the hazard communication training is to be conducted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at F & S Tool, INC.
View F & S Tool, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333514)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340855113.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.