Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S DEPARTMENT OF THE INTERIOR, NATIONAL PARK SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S DEPARTMENT OF THE INTERIOR, NATIONAL PARK SERVICE in 1 BLACK CANYON ROAD, ESSEX, CA 92332 (NAICS 712190). OSHA activity number 340861152.

Watch U.S Department OF THE Interior, National Park Service — free Get an email when a new federal OSHA severe-injury report for U.S Department OF THE Interior, National Park Service is published. One employer, no account, unsubscribe in one click.
Site address
1 BLACK CANYON ROAD
City
ESSEX
State
CA
ZIP
92332
Mailing
2701 BARSTOW ROAD, BARSTOW, CA 92311
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
15
Ownership type
D

6 citations on file for this inspection.

1910.157 C01

Repeat Gravity 5 1 instance 2 exposed
Issued
Oct 14, 2015
Abate by
Nov 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) Maintenance Shop: On or about August 12, 2015 and times prior, employees are exposed to fire due to portable fire extinguisher being blocked by trash can.  THE DEPARTMENT OF THE INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1050139, CITATION 02, ITEM NUMBER 002 AND WAS AFFIRMED AS A FINAL ORDER ON JULY 30, 2015 WITH RESPECT TO A WORKPLACE LOCATED AT NATIONAL PARK SERVICE JOSHUA TREE NATIONAL PARK, BLACK ROCK NATURE CENTER, 9800 BLACK ROCK CANYON ROAD, YUCCA VALLEY, CALIFORNIA 92284.
Recent events (1)
  • — Z (R) $0

1910.212 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Oct 14, 2015
Abate by
Nov 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Maintenance Shop: On or about August 12, 2015 and times prior, employees were exposed to caught in hazards while working on the Delta 14" Vertical Drill Press 14-070 with an unguarded chuck.  THE DEPARTMENT OF THE INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 994168, CITATION 01, ITEM NUMBER 007 AND WAS AFFIRMED AS A FINAL ORDER ON FEBRUARY 13, 2015 WITH RESPECT TO A WORKPLACE LOCATED AT NATIONAL PARK SERVICE GRAND CANYON, SOUTH RIM WASTE WATER TREATMENT PLANT, 1 ROWE WELL ROAD, GRAND CANYON, ARIZONA 86023.
Recent events (1)
  • — Z (R) $0

1910.305 B02 I

Repeat Gravity 5 1 instance 5 exposed
Issued
Oct 14, 2015
Abate by
Nov 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:(a) (LOCATION) (IDENTIFY EQUIPMENT AND CONDITION(S)) (STATE HAZARD(S) TO EMPLOYEE(S))  (a) Training Room: On or about August 12, 2015 and times prior, employees are exposed to electric shock/fire by using an electrical outlet with missing faceplate.  THE DEPARTMENT OF THE INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1050143, CITATION 01, ITEM NUMBER 002 AND WAS AFFIRMED AS A FINAL ORDER ON JULY 30, 2015 WITH RESPECT TO A WORKPLACE LOCATED AT NATIONAL PARK SERVICE JOSHUA TREE NATIONAL PARK, BLACK ROCK INTERAGENCY FIRE CENTER, 9800 BLACK ROCK CANYON ROAD, YUCCA VALLEY, CALIFORNIA 92284.
Recent events (1)
  • — Z (R) $0

1910.305 G01 IV A

Repeat Gravity 5 3 instances 5 exposed
Issued
Oct 14, 2015
Abate by
Nov 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   (a) TV Room: On or about August 12, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord attached to an Uninterruptable Power Unit.  (b) Training Room: On or about August 12, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord attached to a Relocatable Power Tap.  (c) Training Room: On or about August 12, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord attached to a Pedestal Fan.  THE DEPARTMENT OF THE INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 992639, CITATION 01, ITEM NUMBER 017 AND WAS AFFIRMED AS A FINAL ORDER ON FEBRUARY 3, 2015 WITH RESPECT TO A WORKPLACE LOCATED AT NATIONAL PARK SERVICE GRAND CANYON, HEADQUARTERS, 20 SOUTH ENTRANCE ROAD, GRAND CANYON ARIZONA 86023.
Recent events (1)
  • — Z (R) $0

1910.305 G02 III

Repeat Gravity 5 1 instance 2 exposed
Issued
Oct 14, 2015
Abate by
Nov 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Maintenance Shop: On or about August 12, 2015 and times prior, employees are exposed to electric shock/fire by using a Porter Cable Angle Grinder with a 120 volt flexible power cord with electrical tape covering the sheath pulled away from the handle attachment.  THE DEPARTMENT OF THE INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1050066, CITATION 02, ITEM NUMBER 004 AND WAS AFFIRMED AS A FINAL ORDER ON JULY 30, 2015 WITH RESPECT TO A WORKPLACE LOCATED AT NATIONAL PARK SERVICE JOSHUA TREE NATIONAL PARK, PINTO WYE COMPOUND, JOSHUA TREE CALIFORNIA 92284.
Recent events (1)
  • — Z (R) $0

1910.305 J02 IV

Repeat Gravity 5 1 instance 5 exposed
Issued
Oct 14, 2015
Abate by
Nov 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:   (a) Kitchen: On or about August 12, 2015 and time prior, employees were exposed to electric shock/fire due to using electrical outlet near a sink was not protected by GFCI.   (b) Maintenance Shop, Outdoor Outlet: On or about August 12, 2015 and time prior, employees were exposed to electric shock/fire due to using the Delta 14" Vertical Drill Press 14-070 when connected to an electrical outlet outdoors that was not protected by GFCI.   THE DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, CHANNEL ISLANDS NATIONAL PARK WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 899100, CITATION 01, ITEM NUMBER 007 AND WAS AFFIRMED AS A FINAL ORDER ON JUNE 24, 2013, WITH RESPECT TO A WORKPLACE LOCATED AT 1901 SPINNAKER DRIVE, VENTURA, CALIFORNIA 93001.