PATASKALA, OH —
OSHA Inspection: ADELZON AGUILARA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADELZON AGUILARA in 159 ALMAHURST ROAD, PATASKALA, OH 43062 (NAICS 238130). OSHA activity number 340865054.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADELZON AGUILARA
- Site address
- 159 ALMAHURST ROAD
- City
- PATASKALA
- State
- OH
- ZIP
- 43062
- Mailing
- 2702 CHRISTIAN BLVD, COLUMBUS, OH 43231
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1903.19 C01
- Issued
- Feb 2, 2016
- Abate by
- Mar 4, 2016
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section: a. In regards to citation 1, item 1, issued on September 8, 2015, the employer has failed to submit abatement certification within ten days of the abatement date, September 26, 2015. The violation read as follows: 29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed: a. The self supported ladder was leaned up against the scaffold and was used for access, thereby exposing employees to a fall hazard of six feet, three inches.
Recent events (1)
- — Z (O) $400
1926.404 F06
- Issued
- Sep 8, 2015
- Abate by
- Sep 26, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a. The extension cord used to power the air compressor was missing the grounding pin, thereby exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.405 G02 IV
- Issued
- Sep 8, 2015
- Abate by
- Sep 26, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws. a. The flexible cord used to power the air compressor was pulled from the strain relief at the entry point into the compressor, thereby exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.451 G01 VII
- Issued
- Sep 8, 2015
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a. Employees were working from a beam that was between external walls of the new house, the employee was performing framing work from the scaffold without fall protection and exposed to a fall hazard of 6 feet 3 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.501 B13
- Issued
- Sep 8, 2015
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. a. Employees were observed exiting the scaffold onto the framed roof between the trusses without fall protection or a site specific fall protection plan that meets the criteria set forth in 1926.502, thereby exposing employees to a fall hazard of 11 feet 6 inches.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B04
- Issued
- Sep 8, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. a. The self supported ladder was leaned up against the scaffold and was used for access, thereby exposing employees to a fall hazard of 6 feet 3 inches.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections at Adelzon Aguilara
View Adelzon Aguilara's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340865054.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.