On , OSHA opened a planned safety inspection of ADELZON AGUILARA in 1824 AZALIA LANE, PATASKALA, OH 43062 (NAICS 238130). OSHA activity number 340908227.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adelzon Aguilara — free Get an email when a new federal OSHA severe-injury report for Adelzon Aguilara is published. One employer, no account, unsubscribe in one click.
Establishment
ADELZON AGUILARA
Site address
1824 AZALIA LANE
City
PATASKALA
State
OH
ZIP
43062
Mailing
2702 CHRISTIAN BLVD, COLUMBUS, OH 43231
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.404 F06

Deleted Serious Gravity 5 3 instances 5 exposed
Issued
Oct 1, 2015
Abate by
Oct 16, 2015
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  a. Employees were using flexible cords without a grounding pin, thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2200

1926.405 A02 II I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Oct 1, 2015
Abate by
Oct 21, 2015
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage.  a. The employees were using a circular saw with a damaged flexible cord, thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2200

1926.405 G02 IV

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Oct 1, 2015
Abate by
Oct 21, 2015
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  a. The flexible cord used to power the compressor was not provided with strain relief, thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2200

1926.501 B13

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Oct 1, 2015
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  a. Employees were observed framing the roof of the multilevel single family home without fall protection, thereby exposing the employees to a fall hazard of 15 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1926.1053 B04

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Oct 1, 2015
Abate by
Oct 16, 2015
Penalty
Initial $2,640 · Current $0 Reduced
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.  a. Employees had set up an A Frame ladder on the second floor in order to gain access to the roof via a skylight, thereby exposing employees to a fall hazard of 8 feet.