DOVER, DE —
OSHA Inspection: R & J CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of R & J CONSTRUCTION, INC. in LEANDER LAKES APARTMENTS BLDG 1 DOVER HIGH DRIVE, DOVER, DE 19904 (NAICS 238160). OSHA activity number 340867738.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R & J CONSTRUCTION, INC.
- Site address
- LEANDER LAKES APARTMENTS BLDG 1 DOVER HIGH DRIVE
- City
- DOVER
- State
- DE
- ZIP
- 19904
- Mailing
- P.O. BOX 3001, WILMINGTON, DE 19804
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 19, 2016
- Penalty
- Initial $3,080 · Current $2,156 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by a guardrail system, safety net system, or personal fall arrest system, or an alternative fall protection measure that meets a provision described in paragraph (b) of this section. a) Leander Lakes Apartments Building #1, Dover High Drive, Dover, DE - On or about August 21, 2015, the employer did not ensure employees used fall protection while working on the roof approximately 35 feet above the grade, exposing employees to fall hazards.
Recent events (2)
- — I (S) $2156
- — Z (S) $3080
1926.1053 B01
- Issued
- Jan 19, 2016
- Penalty
- Initial $2,200 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access and was not secured: a) Leander Lakes Apartments Building #1, Dover High Drive, Dover, DE - On or about August 21, 2015, the employer did not ensure employees used ladder that extended at least 3 feet above the upper landing or was secured for roof access, exposing employees to fall hazards.
Recent events (2)
- — I (S) $1540
- — Z (S) $2200
More inspections at R & J Construction, INC.
View R & J Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340867738.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.