WHEATON, IL —
OSHA Inspection: DON BOSCO LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DON BOSCO LLC in 812 IRVING, WHEATON, IL 60187 (NAICS 238130). OSHA activity number 340873546.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DON BOSCO LLC
- Site address
- 812 IRVING
- City
- WHEATON
- State
- IL
- ZIP
- 60187
- Mailing
- 2 S 870 NELSON LAKE ROAD, BATAVIA, IL 60510
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 17, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $70,000 · Current $24,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: Employees are exposed to fall hazards while engaged in residential construction activities 6 feet or more above lower levels. The employer does not protect each employee by means of a guardrail system, safety net system, personal fall arrest system, or an alternative fall protection measure. This following instances most recently occurred on August 25, 2015, at the above addressed jobsite: a) Employees engaged in residential construction activities are not protected from falling through an unguarded window, thereby exposing employees to a 13 foot fall hazard from the second floor to grade. b) Employees engaged in residential construction activities are not protected from falling through floor holes, thereby exposing employees to a 10 foot fall hazard from the first floor to the basement and from the second floor to the first floor. c) An employee engaged in residential construction activities was not protected from falling from a roof during sheeting operations, thereby exposing employees to an 11.5 foot fall hazard from the roof. To abate this hazard in the future, the employer must ensure that its employees performing residential construction activities are protected from falls, and that no employee is exposed to a six foot fall or greater without adequate fall protection. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
- — F (W) $24000
- — C (W) $70000
- — Z (W) $70000
1926.416 E01
- Issued
- Dec 17, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $4,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used. On August 25, 2015, employees were using worn and frayed electrical cords, thereby exposing employees to the hazards associated with an electrical shock. The employer did not ensure worn or frayed electrical cords were not used. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
- — F (S) $1000
- — C (S) $4000
- — Z (S) $4000
1926.1052 C01 II
- Issued
- Dec 17, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $5,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge. On August 25, 2015, employees were using a stairway not equipped with a compliant stair rail system to access the second floor working area, thereby exposing employees to fall hazards of approximately 10 feet. The employer did not ensure stairways having four or more risers were equipped with a stair rail system. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
- — F (S) $2000
- — C (S) $5000
- — Z (S) $5000
1926.1052 C12
- Issued
- Dec 17, 2015
- Abate by
- Dec 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems which met the criteria contained in Subpart M of 29 CFR 1926: On August 25, 2015, employees working the second floor of a residential property were not protected by a guardrail which met the criteria set forth in subpart M, thereby exposing employees to a fall hazard of approximately 10 feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at DON Bosco LLC
View DON Bosco LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340873546.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.