Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: V & T PAINTING, LLC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of V & T PAINTING, LLC. in 1205 CHESTNUT ST., CHILTON, WI 53014 (NAICS 238320). OSHA activity number 340878388.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch V & T Painting, LLC. — free Get an email when a new federal OSHA severe-injury report for V & T Painting, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1205 CHESTNUT ST.
City
CHILTON
State
WI
ZIP
53014
Mailing
29585 GRAMERCY CT., FARMINGTON HILLS, MI 48336
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.62 D01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 12, 2016
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.62(d)(1)(i): Each employer who has a workplace or operation covered by this standard shall initially determine if any employee may be exposed to lead at or above the action level.  a.  On or about August 27, 2015, the employer did not perform an initial assessment of the Lead exposure to employees removing paint using an abrasive blasting method from the water tower located at 1149 East Chestnut Street Chilton, Wisconsin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2200

1926.62 H01

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 11, 2015
Abate by
Jan 12, 2016
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.62(h)(1): "All surfaces shall be maintained as free as practicable of accumulations of lead".  Employees removing Lead-based paint from a water tower using an abrasive blasting method were exposed to Lead from contaminated surfaces in the decontamination trailer.    a.  Wipe samples of the inside door handle of the exit door of the "clean" side of the decontamination trailer had a Lead level of 31.785 ug/16 in2 which equates to 286 ug/ft2.    b.  Wipe samples of shower side door handle of the door between the showers and the "clean" side of the decontamination trailer had a Lead level of 77.255 ug/16 in2 which equates to 695 ug/ft2.    c.  Wipe samples of the top surface of a bench in the "clean" side of the decontamination trailer had a Lead level of 138.140 ug/16 in2 which equates to 1243 ug/ft2.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $2200

1926.62 I01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Dec 11, 2015
Abate by
Jan 12, 2016
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.62(i)(1): The employer shall assure that in areas where employees are exposed to lead above the PEL without regard to the use of respirators, food or beverage is not present or consumed, tobacco products are not present or used, and cosmetics are not applied.  a.  In the ARS Decontamination Trailer by the water tower located at 1149 East Chestnut Street Chilton, Wisconsin, two water bottles were observed in a contaminated changing trailer.  Cigarette butts were observed on the ground outside of the trailer.  "Ghost Wipe" samples taken from inside and outside of the trailer indicated elevated Lead levels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2200

1926.62 I03 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Dec 11, 2015
Abate by
Jan 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.62(i)(3)(i): The employer shall provide shower facilities, where feasible, for use by employees whose airborne exposure to lead is above the PEL.  a.  At the jobsite located at 1149 East Chestnut Street Chilton, Wisconsin, the employer did not provide adequate shower facilities to employees exposed to Lead.  Decontamination trailer observed on September 9, 2015 did not have the supplied Aluminum folding stairs in place by the "dirty" side door requiring the employees to enter and exit through the "clean" side to access the showers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.62 I04 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Dec 11, 2015
Abate by
Jan 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.62(i)(4)(i): The employer shall provide lunchroom facilities or eating areas for employees whose airborne exposure to lead is above the PEL, without regard to the use of respirators.  a.  Employees were exposed to Lead while drinking water in the decontamination trailer and smoking cigarettes on the job site.  Water bottles were inside the decontamination trailer and cigarette butts were on the ground near the decontamination trailer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View V & T Painting, LLC.'s full OSHA safety record →