WEST SENECA, NY —
OSHA Inspection: SAHLEM?S ROOFING & SIDING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAHLEM?S ROOFING & SIDING INC. in 511 UNION ROAD, WEST SENECA, NY 14224 (NAICS 238160). OSHA activity number 340884535.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAHLEM?S ROOFING & SIDING INC.
- Site address
- 511 UNION ROAD
- City
- WEST SENECA
- State
- NY
- ZIP
- 14224
- Mailing
- 2260 SOUTHWESTERN BOULEVARD, WEST SENECA, NY 14224
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Sep 30, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: Four employees were exposed to a fall of 20 ft. 7 in. from the work platform of an An Alum-A-Pole Scaffolding System ( pump jack scaffold) that was set up on the west side of the church. The employees were removing old shingles and installing new roofing shingles on the mansard part of the roof. The work platform was situated on the inside of the pole between the pole and the building wall, and was 20 ft. 7 in. above the ground. A 12 in. wide aluminum pik was installed on the outside of the pole, with the bottom of this pik 31 inches above the work platform and the top of this pik 36 inches above the workplatform leaving a vertical gap of 31 inches between the two piks. Proper guardrails require a top rail that is between 38 inches and 45 inches above a work level, and a mid-rail that is approx. half that distance. The 12 in. wide aluminum pik does not meet the specification for a guardrail, and no other fall protection system was utilized. Additionally, the north and south ends of the work platform had no fall protection system installed. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1926.452 J02
- Issued
- Sep 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: Four employees were exposed to a fall of 20 ft. 7 in. from the work platform of an An Alum-A-Pole Scaffolding System ( pump jack scaffold) that was set up on the west side of the church. The employees were removing old shingles and installing new roofing shingles on the mansard part of the roof. The scaffold had 4 vertical poles, and a section set up between each pole. Each pole had multiple sections spliced together vertically for a total height of approx. 45 ft. for each pole. Each pole was secured to the building using only a single triangular brace secured at the top of the building, a height of approx. 36 ft. 6 in. Alum-A-Pole Scaffolding System Set-Up Instructions require that up to 24 ft., one roof or wall brace is required, and above 24 ft. in height, intermediate braces are required, with a maximum of 16 ft. vertical brace spacing anywhere on the pole or poles. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C03
- Issued
- Sep 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: a) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: Four employees were exposed to a fall of 20 ft. 7 in. from the work platform of an An Alum-A-Pole Scaffolding System ( pump jack scaffold) that was set up on the west side of the church. The employees were removing old shingles and installing new roofing shingles on the mansard part of the roof. The scaffold had 4 vertical poles, and a section set up between each pole. None of the poles were plumb. NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B15
- Issued
- Sep 30, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: a) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: Two employees were installing the ice shield on the almost vertically pitched mansard roof on the west side of the church. The employees were kneeling/standing at the edge of the upper flat roof and were leaning over the edge exposed to a fall of approx. 36 ft. 6 in., while installing the ice shield. No fall protection system was being utilized. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1926.20 B02
- Issued
- Sep 30, 2015
- Abate by
- Oct 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: Employees on this jobsite were exposed to hazards such as but not limited to fall hazards from a pump jack scaffold, the edge of a roof, and ladders. No job site safety inspection was conducted by the employer to identify these hazards and correct them before an accident and injuries could occur. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Sep 30, 2015
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: There were two extension ladders (north and south) placed so that employees could access the elevated 20 in. wide aluminum scaffold planks (piks) used as a work platform on the Alum-A-Pole Scaffold. The siderails of the south extension ladder only extended 22 inches above the work platform which was 20 ft. 7 in. above the ground. b) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: The siderails of the wooden ladder used to access the roof at the southwest corner of the school building only extended 24 inches above the gutter which was 10 ft. 8in. above the ground. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3500
- — Z (S) $3500
1926.21 B02
- Issued
- Sep 30, 2015
- Abate by
- Oct 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 8/28/15, on a jobsite at the First Baptist Church of West Seneca, 511 Union Rd., West Seneca, NY: Employees engaged in construction work including roofing work on a mansard roof were not trained to recognize potential hazards on this type of jobsite, including but not limited to falls from roofs, ladders, pump jack scaffolds, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Sahlem?S Roofing & Siding INC.
View Sahlem?S Roofing & Siding INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340884535.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.