BYERS, CO —
OSHA Inspection: KINDER MORGAN INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KINDER MORGAN INC. in 69500 EAST COUNTY ROAD 38, BYERS, CO 80103 (NAICS 237120). OSHA activity number 340891720.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KINDER MORGAN INC.
- Site address
- 69500 EAST COUNTY ROAD 38
- City
- BYERS
- State
- CO
- ZIP
- 80103
- Mailing
- 69500 EAST COUNTY ROAD 38, BYERS, CO 80103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.119 F04
- Issued
- Dec 28, 2015
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel: a) On or about October 1, 2015 and times prior, effective safe work practices had not been developed and implemented for maintenance operations to address the re-installation of plugs into line after the equipment was placed into service. Plugs were missing on at the following locations: 1) Inlet to Vessel (V-1) below Pressure Safety Valve (PSV-12). 2) Level Control Valve (LCV-11) to Vessel (V-11) and outlet from Vessel (V-11).
Recent events (2)
- — I (S) $3000
- — Z (S) $3000
1910.119 D03 I B
- Issued
- Dec 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Information pertaining to the equipment in the process did not include accurate piping and instrument diagrams (P&ID's): a) On or about October 1, 2105, and times prior the employer's piping and instrumentation diagrams (P&ID) were not accurate in that equipment information was found during the walkthrough that was not accurate on the P&ID. Process Safety Valve (PSV-14) was set to release at 960 psig but the P&ID identified the release setting at 1000 psig.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Kinder Morgan INC.
View Kinder Morgan INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237120)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340891720.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.