GREELEY, CO —
OSHA Inspection: ALL AMERICAN PET PROTEINS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALL AMERICAN PET PROTEINS, LLC in 259 30TH STREET, GREELEY, CO 80631 (NAICS 311111). OSHA activity number 340900372.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL AMERICAN PET PROTEINS, LLC
- Site address
- 259 30TH STREET
- City
- GREELEY
- State
- CO
- ZIP
- 80631
- Mailing
- 259 30TH STREET, GREELEY, CO 80631
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311111
- Employees
- 90
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 C01
- Issued
- Mar 2, 2016
- Abate by
- Mar 22, 2016
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(c)(1): Employer did not develop a written plan of action regarding the implementation of the employee participation required: (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015 the employer did not develop a written plan of action regarding the implementation of required employee participation. All American Pet Proteins utilized an ammonia refrigeration system that contained 12,000 pounds of ammonia. The refrigeration system contained 6 plate freezer tables on the production floor whereby anhydrous ammonia was used to cool the freezer plates to subfreezing temperatures. There were no written plans that included employee participation for process safety management. This condition exposed employees to ammonia hazards that included toxic inhalation hazards, corrosive exposure from skin and eye contact, and explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2380
1910.119 F01 III
- Issued
- Mar 2, 2016
- Abate by
- Apr 22, 2016
- Penalty
- Initial $2,975 · Current $2,232 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(iii): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and did not address safety and health considerations: (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015, the employer did not develop and implement written operating procedures for the plate freezer tables to address: 1) The properties of, and hazards presented by the use of ammonia; 2) The precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment; 3) Control measures to be taken if physical contact or airborne exposure occurs; 4) Quality control for the raw materials and control of hazardous chemical inventory levels; and 5) Any special or unique hazards. All American Pet Proteins utilized an ammonia refrigeration system that contained 12,000 pounds of ammonia. The refrigeration system contained 6 plate freezer tables on the production floor whereby anhydrous ammonia was used to cool the freezer plates to subfreezing temperatures. This condition exposed employees to ammonia hazards that included toxic inhalation hazards, corrosive exposure from skin and eye contact, and explosion hazards.
Recent events (2)
- — I (O) $2232
- — Z (S) $2975
1910.119 G01 I
- Issued
- Mar 2, 2016
- Abate by
- Mar 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(g)(1)(i): Each employee presently involved in operating a process was not trained in an overview of the process and in the operating procedures as specified in paragraph (f) of this section. The training did not include emphasis on the specific safety and health hazards, emergency operations including shutdown, and safe work practices applicable to the employee's job tasks: (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015 the employer did not ensure that each employee presently involved in operating the plate freezer tables was trained in the operating procedures as specified in paragraph (f) of this section. The training did not include emphasis on the specific safety and health hazards, emergency operations including shutdown, and safe work practices applicable to the employee's job tasks. All American Pet Proteins utilized an ammonia refrigeration system that contained 12,000 pounds of ammonia. The refrigeration system contained 6 plate freezer tables on the production floor whereby anhydrous ammonia was used to cool the freezer plates to subfreezing temperatures. This condition exposed employees to ammonia hazards that included toxic inhalation hazards, corrosive exposure from skin and eye contact, and explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 J03
- Issued
- Mar 2, 2016
- Abate by
- Mar 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(3): Training for process maintenance activities. The employer did not train each employee involved in maintaining the on-going integrity of process equipment in an overview of that process and its hazards and in the procedures applicable to the employee's job tasks to assure that the employee could perform the job tasks in a safe manner: (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015, the employer did not train the 2nd shift plate freezer maintenance manager involved in maintaining the on-going integrity of the plate freezer equipment to assure that the employee could perform the job tasks in a safe manner. The employer failed to train the employee about the overview of the process, the process hazards, and the procedures applicable to the employee's job tasks to assure that the employee could perform the job tasks in a safe manner. All American Pet Proteins utilized an ammonia refrigeration system that contained 12,000 pounds of ammonia. The refrigeration system contained 6 plate freezer tables on the production floor whereby anhydrous ammonia was used to cool the freezer plates to subfreezing temperatures. This condition exposed employees to ammonia hazards that included toxic inhalation hazards, corrosive exposure from skin and eye contact, and explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 J04 IV
- Issued
- Mar 2, 2016
- Abate by
- Mar 22, 2016
- Penalty
- Initial $1,785 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The employer did not document each mechanical integrity inspection and test that was performed on process equipment: (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015, the employer did not document each inspection, pressure test, and leak test that was performed on the process equipment during the restart of the plate freezer tables following ammonia release incidents 8/27/15, 9/2/15, and 10/14/15. All American Pet Proteins utilized an ammonia refrigeration system that contained 12,000 pounds of ammonia. The refrigeration system contained 6 plate freezer tables on the production floor whereby anhydrous ammonia was used to cool the freezer plates to subfreezing temperatures. This condition exposed employees to ammonia hazards that included toxic inhalation hazards, corrosive exposure from skin and eye contact, and explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $1785
1910.120 Q02
- Issued
- Mar 2, 2016
- Abate by
- Apr 22, 2016
- Penalty
- Initial $2,975 · Current $2,232 Reduced
General-duty citation text
29 CFR 1910.120(q)(2): Elements of an emergency response plan. The employer did not develop an emergency response plan for emergencies which addressed, as a minimum, additional elements of the plan (i) through (xii): (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015, the employer did not develop an emergency response plan for emergencies that included all of the elements of the plan (i) through (xii) stated in this paragraph, in that the plan failed to include the following elements: (iv) Safe distances and places of refuge (v) Site security and control (vi) Evacuation routes and procedures (vii) Decontamination (xi) PPE and emergency equipment All American Pet Proteins utilized an ammonia refrigeration system that contained 12,000 pounds of ammonia. The refrigeration system contained 6 plate freezer tables on the production floor whereby anhydrous ammonia at subfreezing temperatures flows through hollow openings. This condition exposed employees to an ammonia hazard to include inhalation and corrosive exposure from skin and eye contact.
Recent events (2)
- — I (S) $2232
- — Z (S) $2975
1910.120 Q06 I
- Issued
- Mar 2, 2016
- Abate by
- Mar 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.120(q)(6)(i): First responder awareness level. First responders at the awareness level are individuals who are likely to witness or discover a hazardous substance release and who have been trained to initiate an emergency response sequence by notifying the proper authorities of the release. They would take no further action beyond notifying the authorities of the release. First responders at the awareness level did not have sufficient training or sufficient experience to objectively demonstrate competency in the following areas: (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015, the employer did not ensure that employees who evacuated the facility during ammonia releases on 8/27/15, 9/2/15, and 10/14/15 received at least 24 hours of training equal to the first responder level and to provide competency in the following areas: [A] An understanding of what hazardous substances are and the risks associated with them in an incident [B] An understanding of the potential outcomes associated with an emergency created when hazardous substances are present [C] The ability to recognize the presence of hazardous substances in an emergency [D] The ability to identify the hazardous substances, if possible [E] An understanding of the role of the first responder awareness individual in the employer's emergency response plan including site security and control and the U.S. Department of Transportation's emergency Response Guidebook [F] The ability to realize the need for additional resources, and to make appropriate notifications to the communication center All American Pet Proteins utilized an ammonia refrigeration system that contained 12,000 pounds of ammonia. The refrigeration system contained 6 plate freezer tables on the production floor whereby anhydrous ammonia at subfreezing temperatures flows through hollow openings. This condition exposed employees to an ammonia hazard to include inhalation and corrosive exposure from skin and eye contact.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.120 Q06 III
- Issued
- Mar 2, 2016
- Abate by
- Apr 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.120(q)(6)(iii): Employees who participated as hazardous materials technicians, or were expected to participate as hazardous materials technicians, had not received at least 24 hours of training equal to the first responder operations level, and in addition, did not have competency in the areas outlined in 29 CFR 1910.120(q)(6)(iii)(A) through (q)(6)(iii)(I). In addition, the employer did not certify: (a) All American Pet Proteins, 259 30th Street, Greeley, CO 80631: On and before September 2, 2015, the employer directed maintenance managers to serve as hazardous materials technicians, but did not ensure that they were adequately trained as such. The employer directed the maintenance managers to respond to releases or to potential releases of ammonia for the purpose of stopping the release. However, the maintenance managers had not received at least 24 hours of training equal to the first responder operations level. In addition, they were not trained to have competency in the following areas: [A] Know how to implement the employer's emergency response plan; [B] Know the classification, identification, and verification of known and unknown materials by using field survey instruments and equipment; [C] Be able to function within an assigned role in the Incident Command System; [D] Know how to select and use proper specialized chemical personal protective equipment provided to the hazardous materials technician; [E] Understand hazard and risk assessment techniques; [F] Be able to perform advance control, containment, and/or confinement operations within the capabilities of the resources and personal protective equipment available with the unit; [G] Understand and implement decontamination procedures; [H] Understand termination procedures; and [I] Understand basic chemical and toxicological terminology and behavior. This condition exposed employees to ammonia hazards that included toxic inhalation hazards, corrosive exposure from skin and eye contact, and explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ALL American PET Proteins, LLC
View ALL American PET Proteins, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340900372.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.