TAYLORVILLE, IL —
OSHA Inspection: GRANDVIEW BUILDINGS & SUPPLY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GRANDVIEW BUILDINGS & SUPPLY, INC. in 512 N WEBSTER, TAYLORVILLE, IL 62568 (NAICS 452990). OSHA activity number 340900661.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GRANDVIEW BUILDINGS & SUPPLY, INC.
- Site address
- 512 N WEBSTER
- City
- TAYLORVILLE
- State
- IL
- ZIP
- 62568
- Mailing
- 512 N WEBSTER, TAYLORVILLE, IL 62568
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 452990
- Employees
- 10
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.22 A01
- Issued
- Dec 2, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $4,200 · Current $4,200
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: Employees were exposed to tripping hazards: a. while working in the Work Room, Store Room and Dock/Stock Room of the Grandview Outlet because there is merchandise stored and stacked all over. b. while working in the Stock Room of the Home Center because there is merchandise stored and stacked all over.
Recent events (1)
- — Z (S) $4200
1910.22 A02
- Issued
- Dec 2, 2015
- Abate by
- Dec 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: Employees working in the Store Room of the Grandview Outlet were exposed to slips and falls on liquid soap because the walking and working surfaces were not maintained in a clean and dry condition.
Recent events (1)
- — Z (S) $0
1910.23 A08 II
- Issued
- Dec 2, 2015
- Abate by
- Dec 14, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.23(a)(8)(ii): Every floor hole into which persons could accidentally walk were not guarded by a floor hole cover of standard strength and construction: Employees working in the Storeroom of the Grandview Outlet were exposed to trip hazards because the electrical box located in the floor of a walkway was not provided with a cover.
Recent events (1)
- — Z (S) $2100
1910.23 C01
- Issued
- Dec 2, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: An employee working at the Grandview Outlet was exposed to fall hazards because: a. the mezzanine located on the north wall of the Store Room was not guarded by a standard railing or its equivalent. The open sided floor was approximately 9'-0" feet from the open sided floor to the concrete surface below. b. the dock ramp located off the back Dock/Stock Room was not guarded by a standard railing or its equivalent. The open sided floor was approximately 4'-3" feet from the open sided floor to the concrete surface below.
Recent events (2)
- — Z $28000
- — Z (S) $2800
1910.36 D01
- Issued
- Dec 2, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: Employees were exposed to the hazards of smoke inhalation and burns because: a. while working in the Grandview Outlet because the emergency exit located on the north wall of the Work Room contained a locking device that restricted emergency use, such as a bungee cord. b. while working in the Grandview Outlet because the emergency exit located in the northeast wall of the Store Room contained a locking device that restricted emergency use, such as a slide blot. c. while working in the Grandview Outlet because the emergency exit located on the north wall of the Dock/Stock Room contained a locking device that restricted emergency use, such as a deadbolt. d. while working in the Home Center because the emergency exit located on the east wall of the Stock Room contained a locking device that restricted emergency use, such as a metal bar.
Recent events (1)
- — Z (S) $2800
1910.36 D02
- Issued
- Dec 2, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(2): Exit route doors were not free of a device or alarm that could restrict emergency use of the exit route if the device or alarm fails: Employees were exposed to the hazards of smoke inhalation and burns: a. while working in the Grandview Outlet because the emergency exit located on the north wall of the Work Room contained a locking device that restricted emergency use, such as a bungee cord. b. while working in the Grandview Outlet because the emergency exit located on the northeast wall of the Store Room contained a locking device that restricted emergency use, such as a slide bolt. c. while working in the Grandview Outlet because the emergency exit located on the north wall of the Dock/Stock Room contained a locking device that restricted emergency use, such as a deadbolt. d. while working in the Home Center because the emergency exit located on the east wall of the Stock Room contained a locking device that restricted emergency use, such as a metal bar.
Recent events (1)
- — Z (S) $0
1910.36 D03
- Issued
- Dec 2, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(3): Exit route doors were locked from the inside: Employees were exposed to the hazards of smoke inhalation and burns: a. while working in the Grandview Outlet because the emergency exit located on the north wall of the Work Room contained a locking device that restricted emergency use, such as a bungee cord. b. while working in the Grandview Outlet because the emergency exit located on the northeast wall of the Store Room contained a locking device that restricted emergency use, such as a slide bolt. c. while working in the Grandview Outlet because the emergency exit located on the north wall of the Dock/Stock Room contained a locking device that restricted emergency use, such as a deadbolt. d. while working in the Home Center because the emergency exit located on the east wall of the Stock Room contained a locking device that restricted emergency use, such as a metal bar.
Recent events (1)
- — Z (S) $0
1910.36 G02
- Issued
- Dec 2, 2015
- Abate by
- Dec 8, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: Employees working: a. in the Work Room of the Grandview Outlet were exposed to fire and smoke inhalation because the exit access located on the north wall was 13 inches wide. b. in the Stock Room of the Grandview Outlet were exposed to fire and smoke inhalation because the exit access located on the north wall was 25 inches wide.
Recent events (1)
- — Z (S) $2800
1910.36 G04
- Issued
- Dec 2, 2015
- Abate by
- Dec 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(4): Objects that projected into the exit route reduced the width of the exit route to less than the 28 inches minimum width requirements for exit routes: Employees working: a. in the Work Room of the Grandview Outlet were exposed to fire and inhalation because the exit access was 13 inches wide. b. in the Stock Room of the Grandview Outlet were exposed to fire and smoke inhalation because the exit access was 25 inches wide.
Recent events (1)
- — Z (S) $0
1910.37 B02
- Issued
- Dec 2, 2015
- Abate by
- Dec 8, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Employees working in the Work Room of the Grandview Outlet were exposed to the hazards of smoke inhalation and burns because the door located on the north wall was not marked with an Exit sign.
Recent events (1)
- — Z (S) $2800
1910.141 A04 I
- Issued
- Dec 2, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $4,200 · Current $4,200
General-duty citation text
29 CFR 1910.141(a)(4)(i): Receptacle(s) used for putrescible solid or liquid waste or refuse were not equipped with tight fitting cover(s) necessary to maintain sanitary conditions: Cardboard boxes and other containers located in the Back Room of the Grandview Outlet were used for garbage collection and not fitted with suitable covers.
Recent events (1)
- — Z (S) $4200
1910.303 F01
- Issued
- Dec 2, 2015
- Abate by
- Dec 14, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Employees working in the Stock Room of the Home Center were exposed to injury because the disconnect switches were not marked to indicate its purpose.
Recent events (1)
- — Z (S) $2100
1910.303 G01
- Issued
- Dec 2, 2015
- Abate by
- Dec 14, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Employees working in the Stock Room of the Home Center were exposed to injury because the electrical panels were blocked.
Recent events (1)
- — Z (S) $2100
1910.305 B02 I
- Issued
- Dec 2, 2015
- Abate by
- Dec 8, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: An employee working in the Work Room of the Grandview Outlet was exposed to electrical shock hazards because the electrical outlet located on the east wall was not equipped with a suitable cover.
Recent events (1)
- — Z (S) $2800
More inspections at Grandview Buildings & Supply, INC.
View Grandview Buildings & Supply, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 452990)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340900661.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.