TULLYTOWN, PA —
OSHA Inspection: IMAC SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of IMAC SYSTEMS, INC. in 90 MAIN STREET, TULLYTOWN, PA 19007 (NAICS 334514). OSHA activity number 340905504.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IMAC SYSTEMS, INC.
- Site address
- 90 MAIN STREET
- City
- TULLYTOWN
- State
- PA
- ZIP
- 19007
- Mailing
- 90 MAIN STREET P.O. BOX 1605, TULLYTOWN, PA 19007
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334514
- Employees
- 28
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.101 B
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $4,200 · Current $2,900 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Machine Shop - On or about September 9, 2015, Nitrogen cylinders are not being secured while in storage causing a potential for damage. ABATEMENT NOTE: Among others, one acceptable means abatement would be to follow the Compressed Gas Association Pamphlet P-1-2008, Section 5.8.4 Cylinder Positions in Storage: All Compressed gas cylinders in service or storage at user locations shall be secured to prevent falling or rolling.
Recent events (2)
- — I (S) $2900
- — Z (S) $4200
1910.107 C05
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $4,900 · Current $2,900 Reduced
General-duty citation text
29 CFR 1910.107(c)(5): Electrical Equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s): a) Spray Booth - On or about September 9, 2015, an electrical box is installed inside the spray booth on a wooden board and used to power two 150 W Halogen clamp lights and subject to deposits from overspray.
Recent events (2)
- — I (S) $2900
- — Z (S) $4900
1910.307 C02 I
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present: a) Spray Booth - On or about September 9. 2015, an electrical box located within the booth was not approved for the ignitable or combustible properties of the vapors produced by the applied paints. b) Spray Booth - On or about September 9, 2015, two 150 W Halogen clamp lights are installed inside the spray booth not approved for ignitable or combustible properties of the vapors produced by the applied paints.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $4,200 · Current $2,900 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) Worksite - On or about September 9, 2015, the employer did not develop a written Respiratory Protection Program for spray painting and welding operations.
Recent events (2)
- — I (S) $2900
- — Z (S) $4200
1910.134 E02 I
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(2)(i): The employer did not identify a physician or other licensed health care professional (PLHCP) to perform medical evaluations using a medical questionnaire or an initial medical examination that obtained the same information as the medical questionnaire: a) Worksite - On or about September 9, 2015, the employer did not have employees medically evaluated prior to the mandatory use of half mask respirators while spray painting or MIG welding.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Spray Booth Area - On or about September 9, 2015, the employer did not provide fit testing to ensure employees are receiving a tight fit while spray painting.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: a) Spray Booth Area - On or about September 9, 2015, the employer did not ensure that respirators are being stored to protect them from damage or contamination.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H01 I
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition: a) Worksite - On or about September 9, 2015, the employer did not ensure employees who are required to wear half mask respirators on how to properly clean and disinfect after use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) Worksite - On or about September 9, 2015, the employer did not develop a written Hazard Communication Program for the chemicals used in the facility such as, but not limited to, Acetone, Paints, Nitrogen, Xylene.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1910.1200 H01
- Issued
- Oct 9, 2015
- Abate by
- Nov 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Worksite - On or about September 9, 2015, the employer did not provide effective training to employees who are exposed to chemicals, such as but not limited to, Acetone, Paints, Nitrogen and Xylene.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Oct 9, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): a) Worksite - On or about September 9, 2015, the employer did not provide copies of Safety Data Sheets for the chemicals used by employees, such as but not limited to, Acetone, Paints, Nitrogen and Xylene.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Imac Systems, INC.
View Imac Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334514)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340905504.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.