TULLYTOWN, PA —
OSHA Inspection: IMAC SYSTEMS, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of IMAC SYSTEMS, INC. in 90 MAIN STREET, TULLYTOWN, PA 19007 (NAICS 334514). OSHA activity number 340957489.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IMAC SYSTEMS, INC.
- Site address
- 90 MAIN STREET
- City
- TULLYTOWN
- State
- PA
- ZIP
- 19007
- Mailing
- 90 MAIN STREET P.O. BOX 1605, TULLYTOWN, PA 19007
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334514
- Employees
- 28
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 B05 I
- Issued
- Feb 12, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
108025908470
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarm or pressure activated devices were not installed and maintained to indicate or insure that the required air velocity is maintained. a.) Spray Booth - On or about October 1, 2015, An employee spray painting production items with an epoxy coating, was exposed to fire and burn hazards while painting product. The visible airflow gauge was not operational and did indicate that proper airflow was maintained in the spray booth to reduce flammable and toxic vapors to safe levels.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.107 B05 IV
- Issued
- Feb 12, 2016
- Abate by
- Apr 15, 2016
- Penalty
- Initial $0 · Current $0
108025908470
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a.) Spray Booth - On or about October 1, 2015, An employee spray painting production items with an epoxy coating, was exposed to fire and burn hazards while performing production painting with flammable coatings. There was no approved automatic sprinklers in the booth as required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G02
- Issued
- Feb 12, 2016
- Penalty
- Initial $0 · Current $0
108025908470
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a.) Spray Booth - On or about October 1, 2015, An employee spray painting production items with an epoxy coating, was exposed to fire and burn hazards as there was an accumulation of combustible residues on the booths interior walls, and the fan blades.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B09
- Issued
- Feb 12, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
108025908470
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a.) Spray Booth - On or about October 1, 2015, An employee spray painting production items with an flammable coatings was exposed to fire and burn hazards. There was combustible construction and storage surrounding and within 3 feet of the booth. No abatement certification or documentation required.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.107 C06
- Issued
- Feb 12, 2016
- Penalty
- Initial $0 · Current $0
108025908470
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations: a.) Spray Booth - On or about October 1, 2015, An employee spray painting production items with an flammable coating was exposed to fire and burn hazards. An unapproved electrical switch located within 3' of the face of the booth. No abatement certification or documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 E02
- Issued
- Feb 12, 2016
- Penalty
- Initial $0 · Current $0
10802590
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operation(s) exceeded the minimum required for operation: a.) Spray Booth - On or about October 1, 2015, An employee spray painting production items with a flammable coating, was exposed to fire and burn hazards. There was an accumulation of flammable liquids that exceeded the minimum required to be available for daily operations in the vicinity of spraying operations. No abatement certification or documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Imac Systems, INC.
View Imac Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334514)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340957489.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.