OSHA Inspection: FLEXSTAR PACKAGING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLEXSTAR PACKAGING, INC. in 1902 KIMBERLY PARK DRIVE, DALTON, GA 30720 (NAICS 323111). OSHA activity number 340907617.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flexstar Packaging, INC. — free Get an email when a new federal OSHA severe-injury report for Flexstar Packaging, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1902 KIMBERLY PARK DRIVE
City
DALTON
State
GA
ZIP
30720
Mailing
1902 KIMBERLY PARK DRIVE, DALTON, GA 30720
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
30
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 29, 2016
Abate by
Mar 24, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specify procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  (a) Throughout the production area, specific procedures for shutting down, isolating, and securing energy sources were not developed and utilized when servicing and maintaining equipment such as, but not limited to, presses, a laminator, slitters, and bag machines, exposing the employees to electrical and amputation hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.147 C07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 29, 2016
Abate by
Mar 24, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  (a) Throughout the facility, the employer did not provide training to authorized and affected employees to ensure that the employees understood the purpose and the function of the Company's energy control procedures. The employees were exposed to electrical and amputation hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

View Flexstar Packaging, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340907617.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.