REDINGTON BEACH, FL —
OSHA Inspection: AMERICAN ROOFING AND SHEET METAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN ROOFING AND SHEET METAL, INC. in 15701 GULF BLVD, REDINGTON BEACH, FL 33708 (NAICS 238160). OSHA activity number 340911221.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN ROOFING AND SHEET METAL, INC.
- Site address
- 15701 GULF BLVD
- City
- REDINGTON BEACH
- State
- FL
- ZIP
- 33708
- Mailing
- 5425 W CRENSHAW ST., TAMPA, FL 33634
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Nov 12, 2015
- Penalty
- Initial $1,496 · Current $898 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On the 3/12 pitched roof, eye protection was not provided to employees operating pneumatic nail guns, exposing employees to a struck by hazard, on or about 9/11/15.
Recent events (2)
- — I (S) $897.6
- — Z (S) $1496
1926.1053 B08
- Issued
- Nov 12, 2015
- Penalty
- Initial $1,496 · Current $898 Reduced
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: a. In the drive way, the portable extension ladder used to used to climb on the roof was not secured from displacement, exposing employees to a 10 foot fall hazard, on or about 9/11/15.
Recent events (2)
- — I (S) $897.6
- — Z (S) $1496
1926.1053 B12
- Issued
- Nov 12, 2015
- Penalty
- Initial $1,870 · Current $1,122 Reduced
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: a. In the driveway, the metal framed portable extension ladder used to climb on the roof was positioned approximately 2 feet from overhead power lines, exposing employees to an electrical shock hazard, on or about 9/11/15.
Recent events (2)
- — I (S) $1122
- — Z (S) $1870
1926.501 B13
- Issued
- Nov 12, 2015
- Penalty
- Initial $5,280 · Current $3,168 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the 3/12 pitched roof, fall protection was not provided, exposing employees to a 10 foot fall hazard, on or about 9/11/15. American Roofing & Sheet Metal, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1) which was contained in OSHA inspection number 772045, citation number 1, item number 1b and was affirmed as a final order on 19 Feb 2013, with respect to a workplace located at 455 8th ST S. Saint Petersburg, FL 33707. American Roofing & Sheet Metal, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 316073857, citation number 1, item number 1 and was affirmed as a final order on 9 Nov 2011, with respect to a workplace located at 2450 Drew St, Clearwater, FL 33765.
Recent events (2)
- — I (R) $3168
- — Z (R) $5280
More inspections at American Roofing and Sheet Metal, INC.
View American Roofing and Sheet Metal, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340911221.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.