ORRVILLE, OH —
OSHA Inspection: BEKAERT CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BEKAERT CORPORATION in 510 COLLINS BLVD, ORRVILLE, OH 44667 (NAICS 331221). OSHA activity number 340927235.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEKAERT CORPORATION
- Site address
- 510 COLLINS BLVD
- City
- ORRVILLE
- State
- OH
- ZIP
- 44667
- Mailing
- 510 COLLINS BLVD, ORRVILLE, OH 44667
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331221
- Employees
- 2350
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Oct 13, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about 9/4/2015, the employer failed to ensure that employees tasked with putting loops back on the drawblocks of the Vaughn Motoblox CHRX, Serial # 1179, utilized lockout/tagout procedures.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1910.147 D02
- Issued
- Oct 13, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about 9/4/2015, the employer failed to ensure that employees shut down the Vaughn Motoblox CHRX, Serial # 1179, prior to putting wire loops back on the drawblocks.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1910.147 D03
- Issued
- Oct 13, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources: On or about 9/4/2015, the employer failed to ensure that employees physically located, and operated, the pneumatics, and electronics, in such a manner as to isolate the energy sources of the Vaughn Motoblox CHRX, Serial # 1179, prior to putting wire loops back on the drawblocks.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1910.147 D04
- Issued
- Oct 13, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4): A lockout device was not attached to all power sources: On or about 9/4/2015, the employer failed to ensure that employees attached a lockout device to the pneumatics, and electronics, of the Vaughn Motoblox CHRX, Serial # 1179, prior to putting wire loops back on the drawblocks.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1910.147 D05 I
- Issued
- Oct 13, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: On or about 9/4/2015, the employer failed to ensure that employees relieved pneumatic pressure, and disconnected the electronics, of the Vaughn Motoblox CHRX, Serial # 1179, prior to putting wire loops back on the drawblocks.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1910.147 D06
- Issued
- Oct 13, 2015
- Abate by
- Oct 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished: On or about 9/4/2015, the employer failed to ensure that employees verified that pneumatic pressure was relieved, and the electronics were powered off, of the Vaughn Motoblox CHRX, Serial # 1179, prior to putting wire loops back on the drawblocks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Bekaert Corporation
View Bekaert Corporation's full OSHA safety record →
More inspections in this industry (NAICS 331221)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340927235.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.