BYESVILLE, OH —
OSHA Inspection: HEATING AND COOLING PRODUCTS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HEATING AND COOLING PRODUCTS in 356 W. MAIN ST., BYESVILLE, OH 43723 (NAICS 332116). OSHA activity number 340927367.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEATING AND COOLING PRODUCTS
- Site address
- 356 W. MAIN ST.
- City
- BYESVILLE
- State
- OH
- ZIP
- 43723
- Mailing
- 356 W. MAIN ST., BYESVILLE, OH 43723
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 82
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Nov 18, 2015
- Abate by
- Feb 1, 2016
- Penalty
- Initial $6,930 · Current $6,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The control of hazardous energy (lockout/tagout). General - Energy control procedure. The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a. On or about September 10, 2015, the employer's energy control procedure did not include the shutting down and isolating of automatic elbow machines, including machine 1228, during knife clearance adjustment, head adjustment and related setup activities. Due to this condition, employees are at increased risk for injury and on this date an employee performing troubleshooting that involved head adjustment, suffered a serious injury to two fingers of his left hand.
Recent events (2)
- — I (S) $6300
- — Z (S) $6930
1910.147 D
- Issued
- Nov 18, 2015
- Abate by
- Feb 1, 2016
- Penalty
- Initial $6,930 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: 29 CFR 1910.147(d)(1): Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy. 29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. 29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a. On or about September 10, 2015, the employer failed to require that automatic elbow machines, such as machine 1228, are turned off or shut down and that energy isolating devices are applied to the machines during setup activities that include head adjustment and knife clearance adjustment. These activities are also performed as part of troubleshooting production problems without machine shutdown or energy isolating device application. On this date, an employee performing elbow machine troubleshooting that involved head adjustment suffered serious injury to two fingers of his left hand.
Recent events (2)
- — I (S) $0
- — Z (S) $6930
1910.212 A02
- Issued
- Nov 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. a. On or about September 17, 2015, the barrier guard for automatic elbow machine 1191 was not properly fastened or affixed to the machine. A fastener was missing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Heating and Cooling Products
View Heating and Cooling Products's full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340927367.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.