Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCEPTER NEW YORK, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SCEPTER NEW YORK, INC. in 11 LAMB RD, SENECA FALLS, NY 13148 (NAICS 331314). OSHA activity number 340946938.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Scepter NEW York, INC. — free Get an email when a new federal OSHA severe-injury report for Scepter NEW York, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11 LAMB RD
City
SENECA FALLS
State
NY
ZIP
13148
Mailing
11 LAMB ROAD, SENECA FALLS, NY 13148
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331314
Employees
70
Ownership type
A

5 citations on file for this inspection.

1910.37 A04

Serious Gravity 1 2 instances 1 exposed
Issued
Feb 5, 2016
Abate by
Feb 25, 2016
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times.    a) Dross storage areas. On or about 9/25/15: Emergency exit doors were found bent and damaged and were unable to open or close.
Recent events (3)
  • — J (S) $1620
  • — C (S) $2700
  • — Z (S) $2700

1910.176 B

Other-than-serious 3 instances 3 exposed
Issued
Feb 5, 2016
Abate by
Mar 24, 2016
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.176(b): Storage of material  created a  hazard.      a) Dross storage area. On or about 9/25/15: Materials in the bin areas were improperly stored and not secure causing it to slide and damage the walls in the bins they were stored in.
Recent events (3)
  • — J (O) $0
  • — C (S) $2700
  • — Z (S) $2700

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2016
Abate by
Mar 11, 2016
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips.    a) Pig Turntable Furnace Area, On or about 9/25/15: Employees are exposed to rotating arms of the pig mold turntable while performing stamping and sampling activities.
Recent events (3)
  • — J (S) $2160
  • — C (S) $3600
  • — Z (S) $3600

1910.304 G05

Other-than-serious 1 instance 1 exposed
Issued
Feb 5, 2016
Abate by
Feb 15, 2016
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.    Furnace  Area, along the exterior wall, On or about 9/25/15: A cooling fan was missing its ground pin exposing employees to ungrounded equipment.
Recent events (3)
  • — J (O) $0
  • — C (S) $2700
  • — Z (S) $2700

1910.23 C01

Serious Gravity 5 7 instances 2 exposed
Issued
Feb 5, 2016
Abate by
Mar 11, 2016
Penalty
Initial $7,920 · Current $1,620 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.     a) Baghouse Area,   On or about 9/25/15: Elevated walkways had a series of  openings of approximately 2' x 3' of which employees could fall 12 feet to the ground below.     b) Furnace Bldg loading dock area, On or about 9/25/15: A open sided floor was missing a proper guardrail that had a fall of greater than 4 feet.      Scepter New York was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.23(c)(1)which was contained in OSHA inspection number 1094693, citation number 1 , item number 1 and was affirmed as a final order on 6/22/11with respect to a workplace located at  11 Lamb Rd, Seneca Falls, NY.
Recent events (3)
  • — J (S) $1620
  • — C (R) $7920
  • — Z (R) $7920

View Scepter NEW York, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340946938.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.