SENECA FALLS, NY —
OSHA Inspection: SCEPTER NEW YORK, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SCEPTER NEW YORK, INC. in 11 LAMB RD, SENECA FALLS, NY 13148 (NAICS 331314). OSHA activity number 340946938.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCEPTER NEW YORK, INC.
- Site address
- 11 LAMB RD
- City
- SENECA FALLS
- State
- NY
- ZIP
- 13148
- Mailing
- 11 LAMB ROAD, SENECA FALLS, NY 13148
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331314
- Employees
- 70
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.37 A04
- Issued
- Feb 5, 2016
- Abate by
- Feb 25, 2016
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times. a) Dross storage areas. On or about 9/25/15: Emergency exit doors were found bent and damaged and were unable to open or close.
Recent events (3)
- — J (S) $1620
- — C (S) $2700
- — Z (S) $2700
1910.176 B
- Issued
- Feb 5, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $2,700 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard. a) Dross storage area. On or about 9/25/15: Materials in the bin areas were improperly stored and not secure causing it to slide and damage the walls in the bins they were stored in.
Recent events (3)
- — J (O) $0
- — C (S) $2700
- — Z (S) $2700
1910.212 A01
- Issued
- Feb 5, 2016
- Abate by
- Mar 11, 2016
- Penalty
- Initial $3,600 · Current $2,160 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips. a) Pig Turntable Furnace Area, On or about 9/25/15: Employees are exposed to rotating arms of the pig mold turntable while performing stamping and sampling activities.
Recent events (3)
- — J (S) $2160
- — C (S) $3600
- — Z (S) $3600
1910.304 G05
- Issued
- Feb 5, 2016
- Abate by
- Feb 15, 2016
- Penalty
- Initial $2,700 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. Furnace Area, along the exterior wall, On or about 9/25/15: A cooling fan was missing its ground pin exposing employees to ungrounded equipment.
Recent events (3)
- — J (O) $0
- — C (S) $2700
- — Z (S) $2700
1910.23 C01
- Issued
- Feb 5, 2016
- Abate by
- Mar 11, 2016
- Penalty
- Initial $7,920 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) Baghouse Area, On or about 9/25/15: Elevated walkways had a series of openings of approximately 2' x 3' of which employees could fall 12 feet to the ground below. b) Furnace Bldg loading dock area, On or about 9/25/15: A open sided floor was missing a proper guardrail that had a fall of greater than 4 feet. Scepter New York was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.23(c)(1)which was contained in OSHA inspection number 1094693, citation number 1 , item number 1 and was affirmed as a final order on 6/22/11with respect to a workplace located at 11 Lamb Rd, Seneca Falls, NY.
Recent events (3)
- — J (S) $1620
- — C (R) $7920
- — Z (R) $7920
More inspections at Scepter NEW York, INC.
View Scepter NEW York, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331314)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340946938.