Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. FOOD AND DRUG ADMINISTRATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. FOOD AND DRUG ADMINISTRATION in 606 TITO CASTRO AVENUE, SUITE 213 LA RAMBLA PLAZA, PONCE, PR 00716 (NAICS 922190). OSHA activity number 340955681.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Food and Drug Administration — free Get an email when a new federal OSHA severe-injury report for U.S. Food and Drug Administration is published. One employer, no account, unsubscribe in one click.
Site address
606 TITO CASTRO AVENUE, SUITE 213 LA RAMBLA PLAZA
City
PONCE
State
PR
ZIP
00716
Mailing
466 FERNANDEZ JUNCOS AVENUE, SAN JUAN, PR 00901
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922190
Employees
3
Ownership type
D

3 citations on file for this inspection.

1910.37 A04

Serious Gravity 1 2 instances 3 exposed
Issued
Dec 10, 2015
Abate by
Jan 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:   a) On or about 9/24/15, at 606 Tito Castro Avenue, Suite 213, La Rambla Plaza, Ponce, PR, in the reception area, the emergency exit light fixture was not in working conditions.   b) On or about 9/24/15, at 606 Tito Castro Avenue, Suite 213, La Rambla Plaza, Ponce, PR, in the hallway area, the emergency exit light fixture was not in working conditions.    PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Dec 10, 2015
Abate by
Jan 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling:   a) On or about 9/24/15, at 606 Tito Castro Avenue, Suite 213, La Rambla Plaza, Ponce, PR, in the Consumer Safety Officer #1 work area, an uninterruptible power supply was not connected to a permanently installed branch circuit receptacle.   b) On or about 9/24/15, at 606 Tito Castro Avenue, Suite 213, La Rambla Plaza, Ponce, PR, in the Consumer Safety Officer #2 work area, a relocatable power tap was not directly connected to a permanently installed branch circuit receptacle.    PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
  • — Z (S) $0

1910.304 B03 I

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 10, 2015
Abate by
Jan 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops shall have ground-fault circuit-interrupter protection for personnel:  On or about 9/24/15, at 606 Tito Castro Avenue, Suite 213, La Rambla Plaza, Ponce, PR, in the bathroom area, electrical receptacles were not equipped with ground-fault circuit-interrupter protection.  PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.