NILES, IL —
OSHA Inspection: SPECIALTY PROMOTIONS, INC. DBA SPECIALTY PRINT COMMUNICATIONS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SPECIALTY PROMOTIONS, INC. DBA SPECIALTY PRINT COMMUNICATIONS, INC. in 7420 N. LEHIGH, NILES, IL 60714 (NAICS 323119). OSHA activity number 340957323.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 7420 N. LEHIGH
- City
- NILES
- State
- IL
- ZIP
- 60714
- Mailing
- 6019 W. HOWARD AVE, NILES, IL 60714
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323119
- Employees
- 350
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Dec 22, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate (a) Facility Wide - The employer failed to ensure that permanent and temporary mechanics were provided with authorized lockout/tagout training to ensure they had the knowledge and skills required for the safe application, usage and removal of energy control when performing servicing and maintenance on machines such as but not limited to insert machines. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.147 C07 I B
- Issued
- Dec 22, 2015
- Abate by
- Feb 12, 2016
- Penalty
- Initial $4,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) Lettershop Department - The employer failed to instruct machine operators in the purpose and use of energy control procedures as affected employees. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2500
- — Z (S) $4000
1910.147 D
- Issued
- Dec 22, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Lettershop Department- The employer did not ensure that employees performing servicing and maintenance on inserting machines were required to: (1) prepare the machine or equipment for shut down, (2) turn off and shut down the machine or equipment, (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source(s), (4) affix lockout or tagout devices to each energy isolating device, and (5) verify isolation and deenergization of the machine or equipment have been accomplished prior to starting service and/or maintenance work. Employees were exposed to amputation hazards associated with the unexpected start-up and energizing of the inserting machine. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.212 A01
- Issued
- Dec 22, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $7,000 · Current $4,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Lettershop Department - The employer did not ensure that the CMC 150 Inserting machine #22 was equipped with permanent panel guards during operation to eliminate employee(s) exposure to rotating belts and pulleys. On September 19, 2015, a temporary employee operating Inserting machine #22 suffered an amputation injury to their finger when they reached into the unguarded mechanical adjustment section and the employee's finger was caught between the belt and pulley. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $4700
- — Z (S) $7000
1910.219 F03
- Issued
- Dec 22, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $7,000 · Current $4,700 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: (a) Lettershop Department - The employer did not ensure that the chain and sprocket located underneath Inserting machine #16 was guarded. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $4700
- — Z (S) $7000
1904.31 B02
- Issued
- Dec 22, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $1,000 · Current $500 Reduced
General-duty citation text
29 CFR 1904.31(b)(2): Work-related injuries and illnesses sustained by employees from a temporary help service, employee leasing service, or personnel supply service, that were supervised by the employer on a day to day basis, were not recorded: (a) On September 20, 2015, a temporary employee sustained a amputation injury to their hand while operating inserting machine #22 in the production department. The injury was not recorded on the OSHA 300 form, the Log of Work-Related Injuries and Illnesses. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $500
- — Z (O) $1000
More inspections at Specialty Promotions, INC. DBA Specialty Print Communications, INC.
View Specialty Promotions, INC. DBA Specialty Print Communications, INC.'s full OSHA safety record →