Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADDISON STEEL TRUSS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADDISON STEEL TRUSS, INC. in 33884 HIGHWAY 278, ARLEY, AL 35540 (NAICS 321214). OSHA activity number 340963826.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Addison Steel Truss, INC. — free Get an email when a new federal OSHA severe-injury report for Addison Steel Truss, INC. is published. One employer, no account, unsubscribe in one click.
Site address
33884 HIGHWAY 278
City
ARLEY
State
AL
ZIP
35540
Mailing
P.O. BOX 225, ADDISON, AL 35540
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321214
Employees
7
Ownership type
A

6 citations on file for this inspection.

1910.136 A

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 12, 2015
Abate by
Nov 24, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.136(a): The employer did not ensure that each affected employee used protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole:  (a) On or about 10/05/2015 - Welding Area, employees working with welding trusses weighing approximately 200 pounds were not required to wear foot protection.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.132 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 12, 2015
Abate by
Nov 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  (a) On or about 10/05/2015 - Welding Area, the employer did not assess the hazards in the welding area associated with working with welding trusses weighing approximately 200 pounds.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A05

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 12, 2015
Abate by
Nov 24, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one-half inch:  (a) On or about 10/05/2015 - Welding Area, the box fan located on the floor had 4-inch openings.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.254 D08

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 12, 2015
Abate by
Nov 24, 2015
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.254(d)(8): Welding cables with splices within 10 feet (3 m) of the holder were used:  (a) On or about 10/05/2015 - Welding Area, Lincoln Welders, Model 525, welding cables were spliced at 2 feet from the holders.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 12, 2015
Abate by
Nov 24, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:  (a) On or about 10/05/2015 - Welding Area, a 270-volt electrical circuit breaker did not have a cover.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.253 B04 III

Other-than-serious 1 instance 3 exposed
Issued
Nov 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) On or about 10/05/2015 - Welding Area, one oxygen cylinder and one acetylene cylinder were stored together.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Addison Steel Truss, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340963826.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.