Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: V&T PAINTING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of V&T PAINTING LLC in RESERVOIR ST., DANVILLE, PA 17821 (NAICS 238320). OSHA activity number 340964188.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch V&T Painting LLC — free Get an email when a new federal OSHA severe-injury report for V&T Painting LLC is published. One employer, no account, unsubscribe in one click.
Establishment
V&T PAINTING LLC
Site address
RESERVOIR ST.
City
DANVILLE
State
PA
ZIP
17821
Mailing
29585 GRAMERCY COURT, FARMINGTON HILLS, MI 48336
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.152 E05

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 1, 2016
Abate by
May 18, 2016
Penalty
Initial $1,760 · Current $1,760
29 CFR 1926.152(e)(5): Dispensing devices and nozzles for flammable liquids were not of an approved type:  a) Water storage tanks, Danville, PA: Employees were gravity dispensing diesel fuel from an elevated storage tank to a compressor through a rubber hose, as observed on or about November 4, 2015.  Abatement Certification Required.
Recent events (3)
  • — F (S) $1760
  • — C (S) $1760
  • — Z (S) $1760

1926.152 E02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 1, 2016
Abate by
May 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.152(e)(2): The transfer of flammable liquids from one container to another was done when the containers were not electrically interconnected (bonded):  a) Water storage tanks, Danville, PA: Employees were gravity dispensing diesel fuel from an elevated storage tank to a compressor through a rubber hose without the containers being electrically interconnected (bonded), as observed on or about November 4, 2015.  Abatement Certification Required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.152 I06

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 1, 2016
Abate by
May 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.152(i)(6): In locations where flammable vapors could have been present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition:  a) Water Storage Tanks, Danville, PA:  Employees were dispensing diesel fuel from an elevated storage tank to a compressor with a rubber hose without the diesel tank being grounded to protect from static, electrical and mechanical sparks, observed on or about November 4, 2015.  Abatement Certification Required
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.403 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 1, 2016
Penalty
Initial $1,320 · Current $1,320
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) Water storage tanks, Danville, PA: A relocatable power tap was being used to supply power to portable electrical equipment including, but not limited to, a battery charger, blasting compressor pot and various flexible cords, as observed on or about November 4, 2015.  Abatement Observed During Inspection.
Recent events (3)
  • — F (S) $1320
  • — C (S) $1320
  • — Z (S) $1320

1926.451 D05 III

Serious Gravity 10 2 instances 3 exposed
Issued
Apr 1, 2016
Abate by
Apr 27, 2016
Penalty
Initial $3,080 · Current $1,760 Reduced
29 CFR 1926.451(d)(5)(iii): Supporting devices were not secured against movement by tiebacks installed at right angles to the face of the building or structure, or opposing angle tiebacks were not installed and secured to a structurally sound point of anchorage on the building or structure:    a) Water storage tanks, Danville, PA: Supporting devices (Crosby shackles and pins), used for supporting suspended scaffolding inside of the water tanks, were not secured against movement by tiebacks, as observed on or about November 9, 2015.    Abatement Certification and Documentation Required.
Recent events (3)
  • — F (S) $1760
  • — C (S) $3080
  • — Z (S) $3080

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 1, 2016
Penalty
Initial $3,080 · Current $2,500 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a) Water storage tank, Danville, PA: An employee was observed working on the roof of the water tank at a height of 40 feet above the ground surface without the use of fall protection, as observed on or about November 9, 2015.
Recent events (3)
  • — F (S) $2500
  • — C (S) $3080
  • — Z (S) $3080

View V&T Painting LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340964188.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.