FORT GREELY, AK —
OSHA Inspection: U.S. ARMY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. ARMY in FMWR, FORT GREELY, AK 99731 (NAICS 713940). OSHA activity number 340974898.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. ARMY
- Site address
- FMWR
- City
- FORT GREELY
- State
- AK
- ZIP
- 99731
- Mailing
- IMPA-GRE-SO, BOX 31269, FORT GREELY, AK 99731
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713940
- Employees
- 158
- Ownership type
- D
Citations
10 citations on file for this inspection.
1910.36 D01
- Issued
- Oct 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: Auto shop; on or about 06 October 2015 times prior thereto, the emergency exit door was locked during business hours. A keyed Master lock was attached via a hasp to the exit door. This condition exposed employees to smoke and fume inhalation, entrapment and fire hazards.
Recent events (1)
- — Z (S) $0
1910.147 C06 I
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Bowling alley; on or about 06 October 2015 and times prior thereto; the employer did not ensure that the control of hazardous energy procedures were inspected annually. The procedures for servicing the pinsetter were not reviewed annually. This condition exposed employees to a caught in hazard.
Recent events (1)
- — Z (S) $0
1910.212 B
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. Outdoor recreation, north work bench; on or about 06 October 2015 and times prior thereto; the employer did not ensure that the Delta bench grinder, serial number 033519W4051, was securely mounted to prevent movement. This condition exposed employees to a struck by hazard.
Recent events (1)
- — Z (S) $0
1910.215 A04
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch. Auto shop; on or about 06 October 2015 and times prior thereto; the work rest on a bench grinder, make and model not legible was not properly adjusted to a maximum of one-eighth of an inch from the abrasive wheel. Two instances were noted: a. On the left hand side; the gap between the abrasive wheel and work rest measured approximately 7/16 of an inch. b. On the right hand side; the gap between the abrasive wheel and work rest measured approximately 1/2 of an inch. This condition exposed employees to a caught in hazard.
Recent events (1)
- — Z (S) $0
1910.219 C02 I
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. Bowling alley, Pin set area; on or about 06 October 2015 and times prior thereto, the employer did not ensure that horizontal shafting was guarded. The chain tensioner shafts on eight of the pinsetter machines were not guarded, exposing employees to rotating parts. This condition exposed employees to a caught in hazard.
Recent events (1)
- — Z (S) $0
1910.304 F01 IV
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel. Outdoor recreation, on or about 06 October 2015 and times prior thereto; the employer did not ensure that the electrical panels were readily accessible. Two instances were noted: a. Behind the main service counter area; a copying machine was stored in front of the electrical panel labeled 01787 impeding immediate access. b. In the customer service area, located in front of the main counter; an electrical panel had a desk and picture board stored in front of the panel impeding immediate access. This condition exposed employees to an electrical shock hazard.
Recent events (1)
- — Z (S) $0
1910.305 B02 I
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy. Auto shop, bay 6; on or about 06 October 2015 and times prior thereto; an energized electrical outlet was missing a faceplate cover. Outlet box was covered with duct tape. This condition exposed employees to electrical shock hazards.
Recent events (1)
- — Z (S) $0
1910.305 E01
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures. Bowling alley, pinsetter area; on or about 06 October 2015 and times prior thereto, the employer did not ensure that an electrical outlet in a wet location was protected. Electrical junction was located adjacent to a humidifier drain pipe. This condition exposed employee to an electrical shock and burn hazards.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. Auto shop and bowling alley; on or about 06 October 2015 and times prior; four instances were noted where energized electrical openings were not effectively closed: a. Auto shop bay 6, circuit labeled 18 - an energized electrical outlet had two knockout plugs missing on the right hand side. b. Auto shop tool room south wall - an energized electrical outlet had a knockout plug missing on the right hand side. c. Bowling alley pinsetter area, adjacent to humidifier drain pipe - an energized electrical box had a knockout plug missing from the top of the box. This condition exposed employees to electrical shock and electrical burn hazard. The U.S. Army Directorate of Family and Morale, Welfare and Recreation was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.305(b)(1)(ii), which was contained in OSHA inspection number 711518, citation number 2, item number 1 and was affirmed as a final order on 12 December 2012, with respect to a workplace located at the Auto shop and Bowling alley.
Recent events (1)
- — Z (R) $0
1910.305 G02 III
- Issued
- Oct 23, 2015
- Abate by
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws. Auto shop and Outdoor Recreation Shops; on or about 06 October 2015 and times prior thereto; two instances were noted where strain relief was not provided: a. Auto shop, bay 6; strain relief was not provided to a blue 25 foot extension cord. b. Outdoor recreation work bench area; strain relief was not provided on the cord to power the work bench outlets. This condition exposed employees to electrical shock and burn hazards. The U.S. Army Directorate of Family and Morale, Welfare and Recreation was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.305(g)(2)(iii), which was contained in OSHA inspection number 712100, citation number 1, item number 2 and was affirmed as a final order on 12 December 2012, with respect to a workplace located at the Auto shop and Outdoor recreation.
Recent events (1)
- — Z (R) $0
More inspections at U.S. Army
View U.S. Army's full OSHA safety record →
More inspections in this industry (NAICS 713940)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340974898.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.