Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VARCO BUILDERS OF TEXAS, LLC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of VARCO BUILDERS OF TEXAS, LLC. in 111 PARK AVE., SAN ANTONIO, TX 78212 (NAICS 236118). OSHA activity number 340978949.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Varco Builders of Texas, LLC. — free Get an email when a new federal OSHA severe-injury report for Varco Builders of Texas, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
111 PARK AVE.
City
SAN ANTONIO
State
TX
ZIP
78212
Mailing
9950 HUNTERS POND, SAN ANTONIO, TX 78224
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.404 B01 III C

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 21, 2016
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.404(b)(1)(iii)(C): The employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage:   APARTMENT COMPLEX: Room 106, on or about October 1 2015, and at times prior thereto, employees were exposed to electrical shock hazards (120 volt/20 amperes) while painting around a receptacle with a shop light that the plug was cut off and the exposed wires were directly inserted into the receptacle.
Recent events (1)
  • — Z (S) $3080

1926.404 F07 IV

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 21, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(7)(iv): Equipment connected by cord and plug. Under any of the conditions described in paragraphs (f)(7)(iv)(A) through (f)(7)(iv)(C) of this section, exposed noncurrent-carrying metal parts of cord- and plug-connected equipment which may become energized were not grounded:   APARTMENT COMPLEX: Room 106, on or about October 1 2015, and at times prior thereto, employees were exposed to electrical shock hazards (120 volt/20 amperes) while painting around a shop light that the ground wire had been cut and not used.
Recent events (1)
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 10 1 instance 5 exposed
Issued
Mar 21, 2016
Abate by
Mar 29, 2016
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:  APARTMENT COMPLEX: Room 112, on or about October 1 2015, and at times prior thereto, employees were exposed to electrical shock hazards (220 volt/20 amperes) while renovating the unit and having the electrical feeder panel unguarded with exposed live electrical conductors.
Recent events (1)
  • — Z (S) $3080

1926.405 J01 I

Serious Gravity 10 16 instances 6 exposed
Issued
Mar 21, 2016
Abate by
Mar 29, 2016
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:  APARTMENT COMPLEX: On or about October 1 2015, and at times prior thereto, employees were exposed to electrical shock hazards (120 volt/20 amperes) while switching lights on/off and plugging into receptacles that had the covers and/or faceplates removed.  a) This violation was observed in rooms: 101, 102, 105, 106, 107, 109, 202, and 203 while employees were switching lights on and off.  b) This violation was observed in rooms: 101, 102, 105, 106, 107, 109, 202, and 203 while employees were plugging in tools to receptacles.
Recent events (1)
  • — Z (S) $3080

View Varco Builders of Texas, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340978949.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.