Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORSOUTH CONSTRUCTION COMPANY OF GEORGIA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NORSOUTH CONSTRUCTION COMPANY OF GEORGIA, INC. in 560 PALLDALE DRIVE, SCOTTDALE, GA 30079 (NAICS 236116). OSHA activity number 340979947.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Norsouth Construction Company of Georgia, INC. — free Get an email when a new federal OSHA severe-injury report for Norsouth Construction Company of Georgia, INC. is published. One employer, no account, unsubscribe in one click.
Site address
560 PALLDALE DRIVE
City
SCOTTDALE
State
GA
ZIP
30079
Mailing
10 CHATHAM CENTER SOUTH SUITE 300, SAVANNAH, GA 31405
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.403 I02 I A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 3, 2016
Abate by
Mar 29, 2016
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.403(i)(2)(i)(A): Live parts of electric equipment operating at 50 volts or more were not kept in a room, vault, or similar enclosure accessible only to qualified persons:   On or about October 8, 2015 on the fourth floor of building 210 other than qualified persons had access to the access to the electrical room.  Inside the electrical room on the fourth floor, the 120/240 electrical panel was energized to provide power to the temporary lights and outlets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1926.405 A02 II C

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2016
Abate by
Mar 29, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.405(a)(2)(ii)(C): Receptacles used on temporary wiring were not of the grounding type.   On or about October 8, 2015 on the second floor of building 210 employees using tools and other equipment were exposed to electric shock as the outlets they received power from were not grounded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.405 D

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 3, 2016
Abate by
Mar 29, 2016
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutouts boxes or enclosures designed for the purpose were not dead front.  On or about October 8, 2015 on the fourth floor of building 210 inside the electrical room on the fourth floor, the 120/240 volt electrical panel was energized to provide power to the temporary lights and the dead front was not installed..
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1926.1402 B

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 3, 2016
Abate by
Mar 29, 2016
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.1402(b): The equipment was assembled or used without ensuring that ground conditions were firm, drained, and graded to a sufficient extent so that, in conjunction (if necessary) with the use of supporting materials, the equipment manufacturer's specifications for adequate support and degree of level of the equipment were met:   On or about October 8, 2015 at 3218 Tobie Circle, Scottsdale, Georgia, employees were exposed working within the lifting zone of the crane were exposed to a struck by hazard when adequate support was not provided to keep the vehicle level.  The boom truck was on a wet, muddy surface without pads.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1926.1417 E01 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 3, 2016
Abate by
Mar 29, 2016
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.1417(e)(1)(iv): Barricades or caution lines, and notices, were not erected to prevent all employees from entering the fall zone. No employees, including those listed in 1926.1425(b)(1) through (3), 1926.1425(d) or 1926.1425(e), are permitted in the fall zone:  On or about October 8, 2015 at 3218 Tobie Circle, Scottsdale, Georgia, employees working with the fall zone of the boom truck were exposed to a struck by hazard when employees were allowed into the fall zone.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

View Norsouth Construction Company of Georgia, INC.'s full OSHA safety record →