OSHA Inspection: MCN BUILD, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MCN BUILD, LLC in 3104 M STREET, NW, WASHINGTON, DC 20007 (NAICS 236220). OSHA activity number 340982008.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MCN Build, LLC — free Get an email when a new federal OSHA severe-injury report for MCN Build, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MCN BUILD, LLC
Site address
3104 M STREET, NW
City
WASHINGTON
State
DC
ZIP
20007
Mailing
1214 28TH STREET, NW, WASHINGTON, DC 20007
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
50
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Other-than-serious 1 instance 1 exposed
Issued
Nov 24, 2015
Abate by
Dec 1, 2015
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a) Lower Level - An electrician was observed installing a new temporary light circuit in an unguarded service panel and exposed to live electrical parts, 120 volt, 200 amp service, on or about 10/13/2015.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (O) $4900
  • — C (S) $4900
  • — Z (S) $4900

1926.451 C01

Other-than-serious 1 instance 2 exposed
Issued
Nov 24, 2015
Abate by
Dec 1, 2015
Penalty
Initial $3,150 · Current $3,150
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph:    a) Exterior, West Wall - Laborers were observed on a tubular welded frame scaffold work platform, 7 ft. wide and  32 ft. high,  handing material to bricklayers on the second story balcony and the scaffold was not secured, on or about 10/13/2015.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
  • — F (O) $3150
  • — C (S) $3150
  • — Z (S) $3150

1926.452 C02

Other-than-serious 1 instance 2 exposed
Issued
Nov 24, 2015
Abate by
Dec 1, 2015
Penalty
Initial $3,150 · Current $3,150
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    a) Exterior, West Wall - Laborers were observed standing on a scaffold work platform 14 feet above the ground and 5 cross braces were missing on the ground level sections, exposing laborers to a collapse hazard, on or about 10/13/2015.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
  • — F (O) $3150
  • — C (S) $3150
  • — Z (S) $3150

1926.1052 B02

Other-than-serious 1 instance 6 exposed
Issued
Nov 24, 2015
Abate by
Dec 1, 2015
Penalty
Initial $2,520 · Current $2,520
29 CFR 1926.1052(b)(2): Foot traffic was not prohibited on skeleton metal stairs where permanent treads and/or landings were to be installed at a later date and the stairs were not fitted with secured temporary treads and/or landings long enough to cover the entire tread or landing area:    a) Apartment Stairway - Masons and laborers were using a metal stairway with a three quarter inch pan and exposed to a trip and fall hazard, on or about 10/13/2015.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
  • — F (O) $2520
  • — C (S) $2520
  • — Z (S) $2520

View MCN Build, LLC's full OSHA safety record →