WASHINGTON, DC —
OSHA Inspection: MCN BUILD, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MCN BUILD, LLC in 3104 M STREET, NW, WASHINGTON, DC 20007 (NAICS 236220). OSHA activity number 340982008.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCN BUILD, LLC
- Site address
- 3104 M STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20007
- Mailing
- 1214 28TH STREET, NW, WASHINGTON, DC 20007
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.416 A01
- Issued
- Nov 24, 2015
- Abate by
- Dec 1, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) Lower Level - An electrician was observed installing a new temporary light circuit in an unguarded service panel and exposed to live electrical parts, 120 volt, 200 amp service, on or about 10/13/2015. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (O) $4900
- — C (S) $4900
- — Z (S) $4900
1926.451 C01
- Issued
- Nov 24, 2015
- Abate by
- Dec 1, 2015
- Penalty
- Initial $3,150 · Current $3,150
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph: a) Exterior, West Wall - Laborers were observed on a tubular welded frame scaffold work platform, 7 ft. wide and 32 ft. high, handing material to bricklayers on the second story balcony and the scaffold was not secured, on or about 10/13/2015. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (O) $3150
- — C (S) $3150
- — Z (S) $3150
1926.452 C02
- Issued
- Nov 24, 2015
- Abate by
- Dec 1, 2015
- Penalty
- Initial $3,150 · Current $3,150
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) Exterior, West Wall - Laborers were observed standing on a scaffold work platform 14 feet above the ground and 5 cross braces were missing on the ground level sections, exposing laborers to a collapse hazard, on or about 10/13/2015. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (O) $3150
- — C (S) $3150
- — Z (S) $3150
1926.1052 B02
- Issued
- Nov 24, 2015
- Abate by
- Dec 1, 2015
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.1052(b)(2): Foot traffic was not prohibited on skeleton metal stairs where permanent treads and/or landings were to be installed at a later date and the stairs were not fitted with secured temporary treads and/or landings long enough to cover the entire tread or landing area: a) Apartment Stairway - Masons and laborers were using a metal stairway with a three quarter inch pan and exposed to a trip and fall hazard, on or about 10/13/2015. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (O) $2520
- — C (S) $2520
- — Z (S) $2520
More inspections at MCN Build, LLC