Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICO RODRIGUEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICO RODRIGUEZ in 1210 W. EXPRESSWAY 83, WESLACO, TX 78599 (NAICS 238140). OSHA activity number 341002004.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Americo Rodriguez — free Get an email when a new federal OSHA severe-injury report for Americo Rodriguez is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICO RODRIGUEZ
Site address
1210 W. EXPRESSWAY 83
City
WESLACO
State
TX
ZIP
78599
Mailing
38811 CIRCLE 6 ST. N, PENITAS, TX 78576
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 C02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 31, 2015
Abate by
Jan 5, 2016
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement:    At the front of this commercial construction site, at the center scaffold section, where bricklaying operations were conducted, scaffolding was constructed with one of the base plates on a wooden block utilized for leveling. The scaffold footplate was partially off the wooden base support and subject to displacement.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $2200

1926.451 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 31, 2015
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toe boards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall.    At the front of this commercial construction site, at the center scaffold section, where bricklaying operations were conducted, employees were exposed to falling objects as bricks were stacked on the scaffold planks and not positioned as to prevent them from falling onto another employee below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2200

1926.451 H02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:     At the front of this commercial construction site, at the center scaffold section, where bricklaying operations were conducted, employees were exposed to falling objects as bricks were stacked on the scaffold planks and toe boards were not provided as to prevent them from falling onto another employee below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Dec 31, 2015
Abate by
Jan 5, 2016
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:    At the front of this commercial construction site, on a scaffold section where bricklaying operations were conducted, a brick cutting saw was utilized with an improperly repaired power cord.  The power cord consisted of two different types of electrical cord. Employees were exposed to electrocution.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2200

View Americo Rodriguez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341002004.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.