Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMMERCIAL STAINLESS FABRICATORS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of COMMERCIAL STAINLESS FABRICATORS, INC. in 1035 COBB INDUSTRIAL DRIVE, MARIETTA, GA 30066 (NAICS 332322). OSHA activity number 341004356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Commercial Stainless Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for Commercial Stainless Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1035 COBB INDUSTRIAL DRIVE
City
MARIETTA
State
GA
ZIP
30066
Mailing
1035 COBB INDUSTRIAL DRIVE, MARIETTA, GA 30066
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
25
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Mar 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a)  Woodworking Area - The employer did not establish a written respiratory protection program, to include training, medical evaluations, and fit testing, for the employee required to wear a 3M full face respirator while spraying an adhesive containing methylene chloride.
Recent events (1)
  • — Z (O) $0

1910.1026 L02 I A

Other-than-serious 1 instance 18 exposed
Issued
Mar 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(l)(2)(i)(A): The employer did not provide appropriate information and training for all employees exposed to chromium (VI), in that employees could not demonstrate knowledge of the contents of the Chromium (VI) standard, 29 CFR 1910.1026:  a)  Welding Department - The employer did not provide training on the hazards associated with chromium VI while employees welded on stainless steel, exposing employees to upper respiratory irritation.
Recent events (1)
  • — Z (O) $0

1910.1052 D02

Other-than-serious 1 instance 2 exposed
Issued
Mar 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride:  a)  Woodworking Area - The employer did not perform initial air monitoring for employees spraying Premier Adhesive PB925, containing methylene chloride, exposing employees to respiratory irritation.
Recent events (1)
  • — Z (O) $0

1910.1052 L01

Other-than-serious 1 instance 2 exposed
Issued
Mar 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1052(l)(1): The employer did not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride:  a)  Woodworking Area - The employer did not provide training on the hazards associated with methylene chloride while employees sprayed Premium Adhesive PB925, exposing employees to upper respiratory and irritation.
Recent events (1)
  • — Z (O) $0

1910.1200 H03 IV

Other-than-serious 1 instance 14 exposed
Issued
Mar 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication training did not include an explanation of the Global Harmonization System (GHS) with respect to the labeling, pictograms, and safety data sheets, including the order of information and how employees could obtain and use the appropriate hazard information:  a) Throughout the facility:  The employer did not provide training to employees on the new Globally Harmonized System of Classification and Labeling of Chemicals (GHS) that took effect December 1, 2013. Employees were not familiar with the new hazard communication standard.
Recent events (1)
  • — Z (O) $0

View Commercial Stainless Fabricators, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341004356.