Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMMERCIAL STAINLESS FABRICATORS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of COMMERCIAL STAINLESS FABRICATORS, INC. in 4986 CANTON RD, MARIETTA, GA 30066 (NAICS 332322). OSHA activity number 343747408.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Commercial Stainless Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for Commercial Stainless Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4986 CANTON RD
City
MARIETTA
State
GA
ZIP
30066
Mailing
4986 CANTON RD, MARIETTA, GA 30066
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
36
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Dec 10, 2021
Abate by
Jan 7, 2022
Penalty
Initial $690 · Current $690
29 CFR  1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.   On or about 8/20/2019, the employer failed to certify to OSHA that the following hazards have been abated.  (a) Production, Polishing/grinding area-  On or about February 5, 2019, and at times prior, the employer exposed an employee to noise hazards, in that the employer failed to establish an audiometric testing program for an employee exposed to noise levels above the Action Level of 85 dBA while polishing and/or grinding metal parts.    An employee polishing and/or grinding metal parts was exposed to continuous noise at 70.89 % of the permissible daily exposure of 85 dBA (time weighted average) or an equivalent sound level of 87.5 dBA during the 435 minute sampling period on February 5, 2019. The exposure calculation included a zero increment for the 45 minutes not sampled.  b) Wood Shop- On or about February 5, 2019, and at times prior, the employer exposed an adhesive sprayer to a health hazard, in that the employer did not provide training on the hazards associated with methylene chloride.  Commercial Stainless Fabricators, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 1910.1052(l)(1), which was contained in OSHA inspection number 1100435, citation number 1, item number 4 and was affirmed as a final order on April 5, 2016, with respect to a workplace located at 1035 Cobb Industrial Drive, Marietta, Georgia 30066.
Recent events (1)
  • — Z (O) $690

1910.95 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 3, 2019
Abate by
Aug 20, 2019
Penalty
Initial $3,580 · Current $3,580

Hazardous substances 8111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:  (a) Production, Polishing/grinding area-  On or about February 5, 2019, and at times prior, the employer exposed an employee to noise hazards, in that the employer failed to establish an audiometric testing program for an employee exposed to noise levels above the Action Level of 85 dBA while polishing and/or grinding metal parts.    An employee polishing and/or grinding metal parts was exposed to continuous noise at 70.89 % of the permissible daily exposure of 85 dBA (time weighted average) or an equivalent sound level of 87.5 dBA during the 435 minute sampling period on February 5, 2019. The exposure calculation included a zero increment for the 45 minutes not sampled.
Recent events (1)
  • — Z (S) $3580

1910.1052 L01

Repeat 1 instance 1 exposed
Issued
Jul 3, 2019
Abate by
Jul 30, 2019
Penalty
Initial $238 · Current $238

Hazardous substances 1730

29 CFR 1910.1052(l)(1): The employer did not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride:  a) Wood Shop- On or about February 5, 2019, and at times prior, the employer exposed an adhesive sprayer to a health hazard, in that the employer did not provide training on the hazards associated with methylene chloride.  Commercial Stainless Fabricators, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 1910.1052(l)(1), which was contained in OSHA inspection number 1100435, citation number 1, item number 4 and was affirmed as a final order on April 5, 2016, with respect to a workplace located at 1035 Cobb Industrial Drive, Marietta, Georgia 30066.
Recent events (1)
  • — Z (R) $238

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Jul 3, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 1730

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) Wood Shop, Adhesive spraying area- On or about February 5, 2019, and at times prior, the employer exposed an employee to a respiratory hazard, in that the employee required to wear a tight-fitting face piece type respirator while spraying adhesive, had not received a medical evaluation to determine his ability to safely wear the respirator.
Recent events (1)
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Jul 3, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 1730

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  (a) Wood Shop, Adhesive spraying area- On or about February 5, 2019, and at times prior, the employer exposed an employee to a respiratory hazard, in that the employee required to wear a tight-fitting face piece type respirator while spraying adhesive, had not received a respirator fit test prior to initial use of the respirator.
Recent events (1)
  • — Z (O) $0

View Commercial Stainless Fabricators, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343747408.