Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VENTILATION SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VENTILATION SERVICES, INC. in 4930 DACOMA ST STE K, HOUSTON, TX 77092 (NAICS 238220). OSHA activity number 341006955.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ventilation Services, INC. — free Get an email when a new federal OSHA severe-injury report for Ventilation Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4930 DACOMA ST STE K
City
HOUSTON
State
TX
ZIP
77092
Mailing
4930 DACOMA ST STE K, HOUSTON, TX 77092
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Deleted Other-than-serious 1 instance 15 exposed
Issued
Nov 19, 2015
Abate by
Dec 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   On or about October 21, 2015, at the facility and on job sites, where employees wear a disposable particulate respirator without providing a medical evaluation to determine the employee's ability to use a respirator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F01

Deleted Other-than-serious 1 instance 15 exposed
Issued
Nov 19, 2015
Abate by
Dec 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  On or about October 21, 2015, at the facility and on job sites, where employees wear a disposable particulate respirator without being fit tested.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Ventilation Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341006955.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.