Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRINITY MARINE PRODUCTS INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of TRINITY MARINE PRODUCTS INC. in 1050 TRINITY ROAD, ASHLAND CITY, TN 37015 (NAICS 336611). OSHA activity number 341017812.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trinity Marine Products INC. — free Get an email when a new federal OSHA severe-injury report for Trinity Marine Products INC. is published. One employer, no account, unsubscribe in one click.
Site address
1050 TRINITY ROAD
City
ASHLAND CITY
State
TN
ZIP
37015
Mailing
1050 TRINITY ROAD, ASHLAND CITY, TN 37015
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
100000
Ownership type
A

5 citations on file for this inspection.

1910.134 E01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 6, 2016
Abate by
May 23, 2016
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.    (a)  On or about October 25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City, TN, an employee was welding on the Panel line wearing a 3M tight fitting respirator and was not medically evaluated to wear it.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $0
  • — C (S) $5000
  • — Z (S) $5000

1910.134 F01

Other-than-serious 1 instance 1 exposed
Issued
Apr 6, 2016
Abate by
May 2, 2016
Penalty
Initial $0 · Current $3,000
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT)    (a)  On or about October 25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City, TN, an employee was welding on the Panel line wearing a 3M tight fitting respirator and the employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate fit test.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (O) $3000
  • — C (S) $0
  • — Z (S) $0

1910.134 K

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 6, 2016
Abate by
May 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary.  On or about October 25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City, TN, an employee was welding on the Panel line wearing a 3M tight fitting respirator and the employer did not provide comprehensive, understandable training.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1915.1000 D01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 6, 2016
Abate by
May 23, 2016
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1915.1000(d)(1)(i): The value of E was exceeded for the 8-hour Time-Weighted Average (TWA) specified in subpart Z for the material involved.  The calculation formula  for E is as follows: E = (CaTa + CbTb + ... + CnTn)/8.    a) On or about October 25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City, TN, an employee was welding steel plates and was exposed to an 8 hour Time Weighted Average concentration of 11.1140 mg/m3 of zinc oxide which is 2 times the permissible exposure limit of 5 mg/m3.  The sample was taken over 462 minutes and zero exposure was assumed for the remaining 18 minutes.  b) On or about October 25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City, TN, an employee was welding steel plates, in the Bottoms Section, and was exposed to an 8 hour Time Weighted Average concentration of Particulates Not Otherwise Regulated (Total Dust) at an 8 hour calculated Time Weighted Average (TWA) of  16.9210 milligrams grams per cubic meter of air which is  1.128 times the 8 hour time weighted average PEL of 15.0 milligrams per cubic meter of air.   c) On or about October 25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City, TN, an employee was welding steel plates, in the Bows and sterns Section, and was exposed to an 8 hour Time Weighted Average concentration of Particulates Not Otherwise Regulated (Total Dust) at an 8 hour calculated Time Weighted Average (TWA) of  22.2490 milligrams grams per cubic meter of air which is 1.483 times the 8 hour time weighted average PEL of 15.0 milligrams per cubic meter of air.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — J (S) $0
  • — C (S) $5000
  • — Z (S) $5000

1915.1000 D02 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 6, 2016
Abate by
May 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1915.1000(d)(2)(i): in case of a mixture of air contaminants an employer shall compute the equivalent exposure as follows:   Em = C1/ L1 +C2/ L2+...Cn/Ln   Where: E(m) is the equivalent exposure for the mixture; C is the concentration of a particular contaminant; L is the exposure limit for that substance specified in Subpart Z of 29 CFR Part 1915.  The value of E(m) shall not exceed unity (1).  On or about October 25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City, TN, an employee was welding and was exposed to an 8 hour Time Weighted Average concentration of 11.1140 mg/m3 of zinc oxide and 0.057 mg/m3 of copper.  Inputting these results into the mixture formula gives a value of E(m) greater than 1 indicating an overexposure.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

View Trinity Marine Products INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341017812.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.